8AL90324ENAAed01      7/22 
1.2.4  Offered Alarm services 
The Alcatel-Lucent Enterprise DECT system coupled to an alarm server offers functionalities such as 
live calls, emergency calls, event keys, status calls, Mandown alarm, no movement alarm, shock 
alarm and pull cord alarm. 
  Live signals are calls that are made automatically (every 90 seconds by default) by the 
handset to the alarm server. The information sent to the alarm server allows the server to 
confirm that the handset has coverage and is working.  
  Emergency calls are initiated by the user pressing and holding (or pressing twice) the 
“Emergency call“ key. 
  Key event calls are also initiated by users when pressing particular keys on the numeric 
keypad and also with the function keys F1/F2 (if “Key event” is activated and F1/F2 keys 
has been programmed in the key settings). These are designed to notify the server that 
certain tasks have been completed, for example, “room is ready“ in the case of a hotel 
application. 
  Status calls are automatically established by the handset each time the handset is plugged 
into or removed from the charger and each time the handset is switched on and off.  
  Mandown, no movement, shock and pull cord alarms are alarms triggered when the set 
detects an abnormal situation. 
 
 
Only emergency calls and event keys calls can be initiated by the user.  
All these features must be activated and configured by the system administrator.