7 Operating instructions
5. When using the unit onboard a ship, first fasten
it firmly with straps (A) or similar to fixing points.
G1104611
N
O
T
E
Never separate an unfiltered system without a strainer
fitted to the pu m p inlet. In such a case, use the special
suction pipe with the built-on strainer.
N
O
T
E
Use the hea ter for b est separation result.
G0912421
Suction pipe (½ ”) with built-on strainer
N
O
T
E
Do not connect the return outlet to a pressuriz e d system
with the same or higher pressure than the pressure
switch set point (50 kPa). Oth erwise the safety function
of the switch will be overridden, which implies that the
pump can operate without flow.
6. Connect the power c
able to the mains. See
also information in
chapter 10 Technical data
on page 69.
N
O
T
E
Be sure the mains fulfil the voltage requ ire m en t. The
frequency converter fitted in the control c ab inet will
cut off the power at voltage spikes or at too high/low
voltage (±10%).
38