7 Operating instructions
When the filler cup is empty, close the valve,
remove the filler cup and fit the protective cap (1)
onto the connection.
N
O
T
E
The filler cup must be removed in order to avoid
vibration.
The feed pump starts automatically
G0906211
When the separator has reached full speed the
feed pump starts. The control system waits for
the pressure to rise. When the pressure has
reached the setpoint (see tile menu for pressure
under 6.1 Operator panel), the feed pump speed
decreases to separation speed and the automatic
pressure regulation starts.
The cleaning unit is now r unning in Production
mode.
N
O
T
E
Make sure that oil is available when starting the pump.
Running dry for a longer period can damage the pump.
!
W
A
R
N
I
N
G
Disintegration hazard
Some vibration can occur for short periods during
the star t phas e wh en the separator passes through
the critical speed. This is normal and passes over
without danger. If the vibrations become very severe
or continue at full speed,
stop the separator
immediately
.See8.7 Separator vibrates on
page 51
for possible causes.
N
O
T
E
Make sure that oil is available when starting the pump.
Running dry for a longer period can damage the pump.
41