6 Technical data
Relubrication interval 50 Hz (3000 rpm)/Relubrication interval 60 Hz (3600 rpm). (Vendor) quantity in Drive End/quantity in
Non Drive End.
6.2 Relubrication intervals
For recommended grease types and general maintenance follow the recommendations in the motor instruction manual.
For relubrication intervals see motor name plate.
For further information contact your local Alfa Laval Technical Support.
Warning: Polyurea based (used on e.g LKH85 motors) must not be mixed with Lithium based grease or vice versa.
6.3 Torque Specifications
Below table specifies the tightening torques for the screws, bolts and nuts in this pump.
Always use below torques if no other values are stated. This can be a matter of personal safety.
Size
Tightening torgue
Nm lbf-ft
M8 20 14.8
M104029.5
M126749.0
M14 110 81.0