Internal supply:
The battery compartment has space for 6 batteries type AA or rechargeable batteries. For
TIMY3 WP you have to use the heat-sealed rechargeable battery-packs ONLY!
-20°C / -4F 20°C / 68F -20°C / -4F 20°C / 68F
Alkaline Batteries about 100 hours not possible not possible
NiMH Rechargeable NM-TIMY2 about 50 hours about 60 hours about 31 hours about 47 hours
Timy3
Timy3 W
Timy3 WP
This measurement took place without the TIMY3 supplying external devices (e. g. no supply of
photocells) and for the WP with 3 printed lines per minute.
Battery types:
Alkaline batteries: These batteries must never be used in a TIMY3 with integrated printer.
Alkaline batteries can only supply about 10 % of their original capacity at temperatures of -
20°C. Thus they are only recommendable for warm weather. On environmental reasons it is
also recommendable that rechargeable batteries are used.
NiMH battery pack NM-TIMY2: The NiMH rechargeable battery pack is recommended for
every TIMY3. These newly developed batteries dispose of an enormous persistence even at
very low temperatures and can supply a high current for the printer.
Charging:
The rechargeable batteries are charged inside the TIMY3 with charger PS12 or PS12A, no
matter if the TIMY3 is switched on or off. The charging period with NiMH batteries (NM-TIMY2)
takes with 1.5 Ah approx. 14 hours.
Charging Switch:
The TIMY3 has got a switch (hidden behind the
battery label) for switching on or off the rechargea-
ble battery charging.
Using alkaline batteries, the charging must be
switched off -position ALKALI-, as otherwise the
batteries may leak.
During the operation with rechargeable batteries,
the switch should be on position NiCd/NiMH so that
the rechargeable batteries are charged.
Attention: Never use alkaline batteries in a
TIMY3 when the charging switch is set
on NiCd/NiMH and a charger is connected.
Operating period:
The operating period depends on the TIMY3 model, the batteries utilized and the ambient
temperature.