EasyManua.ls Logo

ALGE-Timing Timy 3 - Interface Settings; Printer Settings

ALGE-Timing Timy 3
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual
TIMY3 - General
Page 23
10.5 INTERFACE
Settings for the RS232 and scoreboard interface. Some settings are only available in certain
programs.
10.5.1 DISPLAYBOARD
These are settings for ALGE LED displays.
<CONTRAST> adjusts the brightness (0 9) of the LED display board
<TIME + DATE> internal time and date of scoreboard is synchronized
<DISPLAY MODE> without function
<BAUDRATE> standard is 2400, the baud rate of the TIMY3 and also of
the scoreboard is set
<TIMEOUT> period after which the display switches to time of day
<ADRESS> address for LED display board
<SAFETY CAR> display mode permanent or flashing
<LAPS> number of laps
<CTD
LAP> manual or automatic
<FORMAT> output of time of day or play time
10.5.2 RS232
These are settings of the RS232 of the TIMY3.
<MODE>
<BAUDRATE> standard is 9600
<SENDE MEMORY> sends the memory contents of the TIMY3.
<HANDSHAKE>
<TRACK-MODE> norm or ident: change output format (program Track-
timer)
<TIMY<->TIMY> communication between two TIMY3
10.5.3 GSM-MODEM
These are settings of the modem communication of the TIMY3.
<ENTER NR> enter the number to dial
<SEARCH MODEM > search a connected modem
<PIN CODE> enter the SIM card pin code
<STOP GSM-MODEM> disconnect the connection
<MEMORY
SMS send the memory by SMS
10.6 PRINTER
This menu is for setting the printer parameters.
10.6.1 PRINTER-MODE
<PRINTER OFF>
<PRINTER ON > Standard
<PAUSE> Printer stops and times will be saved. Times are printed
when printer is switched on again.
10.6.2 PRINT STARTTIME
< OFF> Standard
< ON >