EasyManua.ls Logo

AlgoForce E1500 - Quick Start Guide; Basic Operation Controls; Accessing and Adjusting Settings; Factory Reset Procedure

Default Icon
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AlgoForce E1500
9
Quick Start
P
ress
Vol/Vibration
buttons to modify Audio
Volume. Hold Vol/Vibration buttons to adjust
Vibration. Press the Backlight Adjust button for
backlight control. Use the Minus and Plus
buttons to modify Sensitivity.
To adjust other settings:
1) Press Right/Auto GB in the Main Detection UI
to access the menu.
2) Navigate with Left/Pinpoint or Right/Auto GB.
3) Modify selected setting with Minus or Plus.
4) Press Return/Auto FS to go back to the Main
Detection UI.
I. Power On
Connect the power bank to the control box and
turn it on. To power the detector, hold the
Power On/Off button for 3 seconds, then
release. Repeat to turn it off.
II. Factory Reset (if necessary)
Hold the Minus and Plus buttons for 3 seconds in
Miscellaneous.
III. Calibrate Coil (see Coil Selection in page 13)
IV. Perform Auto Frequency Scan (Auto FS)
(if necessary to select the quietest frequency to
eliminate electromagnetic interference)
Activate Auto FS by holding the Return/Auto FS
button in the Main Detection UI. The Auto FS
process takes 50 seconds. The noise levels of the
scanned frequencies will be displayed.
V. Set Sensitivity, Audio Settings, and Vibration
(to preferred levels)
Adjust Sensitivity so that the peak of the Real-
time Scrolling Detection Signal is close to the
Detection Threshold when there is no target.
VI. Perform Auto Ground Balance (Auto GB)
(to eliminate ground response)
Hold the Right/Auto GB button. Raise and lower
the coil until the ground response is minimized
or two short beeps are heard, then release the
button. The Auto GB In Progress Indicator flashes
when Auto GB is in progress. Auto GB can be
performed in both the Main Detection UI and
Pinpoint UI.
Main Detection UI
1. Sensitivity
2.
Audio
Threshold
3. Audio Tone
4. Frequency Scan
5. Detection Mode
6.
Mic Volume
7. Coil Selection
8. Miscellaneous
9. Real
-
time
Scrolling
Detection Signal
10. Ground Drift Indicator (G.D.I)
1
1
.
Dual Ground Balance Values
1
2
.
Backlight
Level
1
3
.
High Tone Signal Strength
1
4
.
Soil
Mineralisation
1
5
.
Low Tone
Signal Strength
1
6
.
Vibration
Level
1
7
.
Audio Volume
Level
1
8
.
Selected Coil Size
19. Auto GB In Progress Indicator
20
. Detection Threshold
1 Power On/Off 2 Backlight Adjust
3 Minus 4 Plus
5 Vol/Vibration ↓ 6 Vol/Vibration ↑
7 Left/Pinpoint 8 Return/Auto FS
9 Right/Auto GB
16
4
1 2
3
4
6
5
7
8
9
1
9
12
17
18
20
13
14
15
8
7
6
2
3
5
19
11
10

Other manuals for AlgoForce E1500

Related product manuals