62 Rockwell Automation Publication 1756-RM100F-EN-P - October 2018
Chapter 3 Replacement Considerations with CompactLogix and Compact GuardLogix Systems
Advanced Tab
The Advanced tab provides a way to assign the Controller Fault Handler and
Power-up Handler. You can also match a project to a specific controller by
serial number. The tab is used when the project is offline.
Report Overflow Faults is a new parameter that lets you control Minor
Overflow fault reporting. When you create a project, the default setting
is disabled. When you import or open a legacy project, the default
setting is enabled. For more information, see Minor Fault on Overflow
on page 128.
System Overhead Time Slice is no longer required for 5380 controllers,
and the parameter is removed.
Figure 9 - Controller Properties Dialog Box - Advanced Tab
5370 Controllers 5380 Controllers
Report Overflow Faults is enabled by default when
morphing a legacy project, but defaults to disabled
when creating a CompactLogix 5380 project.

Table of Contents

Other manuals for Allen-Bradley CompactLogix 5380

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley CompactLogix 5380 and is the answer not in the manual?

Allen-Bradley CompactLogix 5380 Specifications

General IconGeneral
BrandAllen-Bradley
ModelCompactLogix 5380
CategoryController
LanguageEnglish

Related product manuals