Publication 1756-5.16 - September 1999
Installation Instructions
ControlLogix
AC (74-265V) Output Module
(Catalog Number 1756-OA8)
7KLVPRGXOHPRXQWVLQD&RQWURO/RJL[FKDVVLVDQGXVHVD5HPRYDEOH7HUPLQDO%ORFN
57%RUD%XOOHWLQ,QWHUIDFH0RGXOH,)0WRFRQQHFWDOOILHOGVLGHZLULQJ
:KHQXVLQJDQ,)0WRZLUH\RXUPRGXOHFRQVXOWWKHLQVWDOODWLRQLQVWUXFWLRQVWKDWFDPHZLWK
LWWRFRQQHFWDOOZLULQJ
%HIRUH\RXLQVWDOO\RXUPRGXOH\RXVKRXOGKDYHDOUHDG\
LQVWDOOHGDQGJURXQGHGDFKDVVLVDQGSRZHUVXSSO\
RUGHUHGDQGUHFHLYHGDQ57%RU,)0DQGLWVFRPSRQHQWVIRU\RXUDSSOLFDWLRQ
To: See page:
Prevent Electrostatic Discharge 2
See Removal and Insertion Under Power (RIUP) 2
Understand Compliance to European Union Directive 3
Note the Power Requirements 4
Identify the Module Components 4
Install the Module 5
Key the Removable Terminal Block/Interface Module 6
Wire the Removable Terminal Block 7
Assemble the Removable Terminal Block and the Housing 9
Install the Removable Terminal Block onto the Module 10
Check the Indicators 11
Remove the Removable Terminal Block from the Module 12
Remove the Module 12
See Specifications 13
Understand CSA Hazardous Location Approval 14
Allen-Bradley HMIs
Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley ControlLogix 1756-IB32 and is the answer not in the manual?

Allen-Bradley ControlLogix 1756-IB32 Specifications

General IconGeneral
Module TypeDigital Input
Input Channels32
Input Voltage CategoryDC
Isolation Voltage50V continuous
Operating Temperature0 to 60 °C
Storage Temperature-40 to 85 °C
Relative Humidity5…95% noncondensing
Module LocationControlLogix Chassis
CompatibilityControlLogix
Point Delay1.0 ms

Summary

Prevent Electrostatic Discharge

Removal and Insertion Under Power (RIUP)

Understand Compliance to European Union Directive

EMC Directive

Details compliance with Council Directive 89/336/EEC for Electromagnetic Compatibility.

Low Voltage Directive

Outlines compliance with Council Directive 73/23/EEC for Low Voltage safety requirements.

Note the Power Requirements

Identify the Module Components

Removable Terminal Block and Housing

Install the Module

Key the Removable Terminal Block/Interface Module

Wire the Removable Terminal Block

Assemble the Removable Terminal Block and the Housing

Install the Removable Terminal Block onto the Module

Check the Indicators

Remove the Removable Terminal Block from the Module

Remove the Module

1756-0A8 Specifications

Agency Certification

CSA Hazardous Location Approval

Related product manuals