16. Verify the drive and motor perform as specified.
Verify that the Stop input is present or the drive will not start.
Verify the drive is receiving the speed reference from the correct place
and that the reference is scaled correctly.
Verify the drive is receiving start and stop commands correctly.
Verify input currents are balanced.
Verify motor currents are balanced.
17. Save a backup of the drive settings using the USB utility application. See
Using the USB Port
on page 63 for more information.
Start, Stop, Direction and Speed Control
Factory default parameter values allow the drive to be controlled from the
keypad. No programming is required to start, stop, change direction and control
speed directly from the keypad.
If a fault appears on power up, see Fault Descriptions
on page 147 for an
explanation of the fault code.
Variable Torque Fan/Pump Applications
For improved motor tuning performance when using a premium efficient motor
on a variable torque loading SVC mode, set A530 [Boost Select] to 2 “35.0, VT.
IMPORTANT
If I/O Terminal 01 is used as a stop input, the jumper between I/O
Terminals 01 and 11 must be removed.
To disable reverse operation, see A544 [Reverse Disable].

Table of Contents

Other manuals for Allen-Bradley PowerFlex 525

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 525 and is the answer not in the manual?

Allen-Bradley PowerFlex 525 Specifications

General IconGeneral
Horsepower0.5-30 HP
kW0.4-22 kW
Input Voltage200-240V AC, 380-480V AC
EnclosureIP20, NEMA/UL Type 1
CommunicationsEtherNet/IP
Control MethodsV/Hz, Sensorless Vector
STOSafe Torque Off (STO)
Output Voltage0-Input Voltage
Operating Temperature-20°C to 50°C (-4°F to 122°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Relative Humidity5-95% non-condensing
DimensionsVaries by model
WeightVaries by model