Interpret the Attribute Tables
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018 101
Attr. ID Access
Rule
Tag Attribute Name B E F P V T C/D Conditional
Implementation
1466 Set
Feedback 2 Cycle Resolution - R - R R R Yes
E; Not Linear Displacement
Transducer (feedback type)
1471 Set
Feedback 2 Data Code - O - O O O Yes
E; Digital Parallel (feedback
type),SSI (feedback type)
1470 Set
Feedback 2 Data Length - O - O O O Yes
E; Digital Parallel (feedback
type),SSI (feedback type)
1469 Set
Feedback 2 Length - R - R R R Yes E; Linear Absolute Only
2450 Set
Feedback 2 Loss Action - O - O O O Yes E
1464 Set
Feedback 2 Polarity - O - O O O Yes E
1475 Set
Feedback 2 Resolver Cable Balance - O - O O O Yes E; Resolver (feedback type)
1474 Set
Feedback 2 Resolver Excitation Frequency - O - O O O Yes E; Resolver (feedback type)
1473 Set
Feedback 2 Resolver Excitation Voltage - O - O O O Yes E; Resolver (feedback type)
1472 Set
Feedback 2 Resolver Transformer Ratio - O - O O O Yes E; Resolver (feedback type)
1451 Get
Feedback 2 Serial Number - - - O O O Yes E
1465 Set
Feedback 2 Startup Method - R - R R R Yes E; Optional Enumeration
1468 Set
Feedback 2 Turns - R - R R R Yes E; Rotary Absolute Only
1463 Set
Feedback 2 Type - R - R R R Yes E; Optional Enumeration
1461 Set
Feedback 2 Unit - R - R R R Yes E
1484 Set
Feedback 2 Velocity Filter Bandwidth - O - O O O Yes E
2453 Set
Feedback 2 Velocity Filter Taps - O - O O O Yes E
250 Set
Feedback Commutation Aligned - - - O O O Yes E; PM Motor only,
Optional Enumeration
31 Set
Feedback Configuration R R R R R R
Optional Enumeration
708 Set
Feedback Data Loss User Limit - O O O O O Yes E
42 Set*
Feedback Mode - R R R R R Yes Derived - Fdbk Config
706 Set
Feedback Noise User Limit - O O O O O Yes E
707 Set
Feedback Signal Loss User Limit - O O O O O Yes E
44 Set
Feedback Unit Ratio - - - O O - Yes E
871 Set
Flux Braking Enable - - O O O O Yes Ind Motor only
528 Get T Flux Current Error - - - O O O Yes
530 Get T Flux Current Feedback - - - O O O Yes
525 Get T Flux Current Reference - - - O O O Yes
557 Set
Flux Integral Time Constant - - - O O O Yes
556 Set
Flux Loop Bandwidth - - - O O O Yes
558 Set
Flux Up Control - - O O O O Yes Ind Motor only,
Optional Enumeration
559 Set
Flux Up Time - - O O O O Yes Ind Motor only
380 Set
Flying Start Enable - - O - O - Yes
381 Set
Flying Start Method - - O - O - Yes V29
570 Set
Frequency Control Method - - R - - - Yes Optional Enumeration
498 Set
Friction Compensation Sliding - - - O O O Yes