Rockwell Automation Publication 20D-TD002L-EN-P - July 2018 105
PowerFlex 700S Drives with Phase II Control
Category Specification Frames 1…6 (690V Drive Frames 5 & 6 Only) Frames 9 & Up
Control Method
Induction Motor:
Brushless Motor:
Sine coded PWM with programmable carrier frequency, Indirect Self-Organized, Field-Oriented Control, Current-regulated. Ratings apply to all
drives. Refer to the PowerFlex 700S Phase II Control Reference Manual, publication PFLEX-RM003…, for derating guidelines. The drive can be
supplied as six-pulse in a configured package.
Carrier Frequency Drive rating: 4 kHz
Settings: 2, 4, 6, 8, 10 kHz
(6 kHz is for V/Hz operation only)
Drive rating: 2 kHz
Settings: 2, 4, 6, 8, 10 kHz
(6 kHz is for V/Hz operation only)
Output Voltage Range: 0 to rated motor voltage 0 to rated motor voltage
Output Frequency Range: 0…400 Hz 0…400 Hz
Note: For output frequencies above 320…400 Hz consult the factory.
Speed Control Speed regulation - without feedback
0.1% of base speed across 120:1 speed range
120:1 operating range
50 rad/sec bandwidth
Speed regulation - without feedback
0.1% of base speed across 120:1 speed range
120:1 operating range
50 rad/sec bandwidth
Speed regulation - with feedback
0.001% of base speed across 120:1 speed range
1000:1 operating range
744 rad/sec bandwidth
Speed regulation - with feedback
0.001% of base speed across 120:1 speed range
1000:1 operating range
300 rad/sec bandwidth
Torque Regulation Torque Regulation - without feedback
5%, 600 rad/sec bandwidth
Torque Regulation - without feedback
10%, 600 rad/sec bandwidth
Torque Regulation - with feedback
2%, 2500 rad/sec bandwidth
Torque Regulation - with feedback
5%, 2500 rad/sec bandwidth
Selectable Motor Control: Field Oriented Control with and without a feedback device and permanent magnet motor control
Stop Modes: Multiple programmable stop modes including – Ramp, Coast, and Current Limit
Accel/Decel Independently programmable accel and decel times adjustable from 0 to 6553.5 in 0.1 second increments
S-Curve Time Adjustable 0.5...4.0 seconds
Intermittent Overload: 110% Overload capability for up to 1 minute
150% Overload capability for up to 3 seconds
Current Limit Capability: Independent Motoring and Regenerative Power Limits programmable to 800% of rated output current
Electronic Motor Overload
Protection
Class 10 motor overload protection according to NEC article 430 and motor over-temperature protection according to NEC article 430.126 (A)(2). UL
508C File E59272.