Rockwell Automation Publication 20D-TD002L-EN-P - July 2018 111
PowerFlex 700S Drives with Phase II Control
Frame Voltage
Class
ND/HD
Rating
(Amps)
Frequency
(kHz)
(1)
(1) Not all frequencies can be run on all drives.
Ambient Temp (C)
(2)
(2) Ambient Temp / Max. Surrounding Air Temperature is the air temperature surrounding the drive module. Rated temperature is 40/40 C (ND/HD) for 400V class drives and 35/40 C (ND/HD) for 600V class drives.
Derate
(2)
10 400 500/420 PWM 50 35 20
1.5 486 573 546
2.0 441 545 618
4.0 323 414 482
6.0 259 341 400
8.0 214 284 284
10.0 184 248 298
600 416/325 PWM 50 35 20
1.5 340 424 492
2.0 332 416 486
4.0 200 264 314
6.0 145 195 241
8.0 109 155 191
10.0 91 127 155
20
25
30
35
40
45
50
55
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500
1.5 kHz
2 kHz
4 kHz
8 kHz
10 kHz
Iout (Amps)
Max. Surrounding Air Temperature °C
6 kHz
20
25
30
35
40
45
50
55
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 375 400 425
Iout (Amps)
1.5 kHz
2 kHz
4 kHz
6 kHz
8 kHz
10 kHz
Max. Surrounding Air Temperature °C