Rockwell Automation Publication 20D-TD002L-EN-P - July 2018 57
PowerFlex 700S Drives with Phase II Control
690 Volt AC Input Frames 9…14 Drive Ratings
Drive Catalog
Number
Frame
kW Rating PWM
Freq.
Temp.
(2)
(2) Maximum air temperature surrounding the drive module.
Input
Ratings
Output Amps Watts
Loss
ND HD kHz C Amps Cont. 1 Min. 3 Sec.
20DF170 9 160 – 2 40 171 170 187 245 3113
– 132 2 40 145 144 216 245 3113
20DF208 9 200 – 2 35 210 208 230 289 3594
– 160 2 40 171 170 250 289 3594
20DF261 10 250 – 2 40 263 261 287 375 4206
– 200 2 40 210 208 312 375 4206
20DF325 10 315 – 2 40 327 325 358 470 4751
– 250 2 40 263 261 392 470 4751
20DF385 10 355 – 2 40 388 385 424 585 5527
– 315 2 40 327 325 488 585 5527
20DF416 10 400 – 2 35 419 416 458 585 5622
– 315 2 40 327 325 488 585 5622
20DF460 11 450 – 2 40 463 460 506 693 6345
– 355 2 40 388 385 578 693 6345
20DF502 11 500 – 2 40 506 502 552 828 6925
– 400 2 40 463 460 690 828 6925
20DF590 11 560 – 2 35 594 590 649 885 7539
– 500 2 35 506 502 753 904 7539
20DF650 12 630 – 2 40 655 650 715 1062 9502
– 560 2 40 594 590 885 1062 9502
20DF750 12 710 – 2 40 756 750 825 1170 10570
– 630 2 40 655 650 975 1170 10570
20DF820
(1)
(1) 20DF820 drives (ND) are only capable of producing 95% of starting torque under 10 Hz.
12 800 – 2 35 826 820 902 1170 11082
– 630 2 35 655 650 975 1170 11082
20DF920 13 900 – 2 40 927 920 1012 1380 12690
– 800 2 40 826 820 1230 1410 12690
20DF1K0 13 1000 – 2 40 1038 1030 1133 1545 15907
– 900 2 40 927 920 1380 1755 15907
20DF1K1 13 1100 – 2 35 1189 1180 1298 1755 17306
– 1000 2 35 1038 1030 1463 1755 17306
20DF1K5 14 1500 – 2 40 1511 1500 1650 2250 22500
– 1300 2 40 1310 1300 1950 2340 22500