Table 12
Table 12 (continued)
Electrical Specifications
Voltage Designation Standard Electric Heat
Capacity
lb. (l)
Code
Voltage
Cycle
Phase
Wire
Full
Load
Amps
Circuit
Breaker
AWG
/mm
2
Full Load
Amps
(Heating
Element
kW)
(Voltage)
Circuit
Breaker
AWG
/mm
2
35
(165)
C 380-415 50/60 3 3+N+PE 10 16 14/2.5
20,8 -12Kw (380V)
25 10/2.5
24,3 - 12Kw (415V)
30,4 - 18Kw (380V)
40 8/4
35,7 - 18Kw (415V)
N 440-480 50/60 3 3+PE 4.1 10 14/2.5
24,9 - 18Kw (440V)
32 8/4
29,4 - 18Kw (480V)
P 380-415 50/60 3 3+PE 4.1 6 14/2.5
19,3 - 12Kw (380V)
25 10/2.5
23 -12Kw (415V)
28,6 - 18Kw (380V)
40 8/4
33,9 - 18Kw (415V)
Q 200-240 50/60 3 3+PE N/A
40 - 18kW (208V)
63 6/6
52,3 - 18Kw (240V)
X 200-240 50/60 1/3 2/3+PE 10 16 14/2.5 N/A
55
(235)
C 380-415 50/60 3 3+N+PE 16 20 14/2.5
31,4 - 18Kw (380V)
40 8/4
36,7 - 18Kw (415V)
N 440-480 50/60 3 3+PE 6.5 16 14/2.5
25,3 - 18Kw (440V)
32 8/4
29,8 - 18Kw (480V)
P 380-415 50/60 3 3+PE 6.5 10 14/2.5
29 - 18Kw (380V)
40 8/4
34,2 - 18Kw (415V)
Q 200-240 50/60 3 3+PE N/A
41 - 18Kw (200V)
63 6/6
53,3 - 18Kw (240V)
X 200-240 50/60 1/3 2/3+PE 16 20 14/2.5 N/A
75
(305)
C 380-415 50/60 3 3+N+PE 9 16 14/2.5
41,7 - 24Kw (380V)
63 6/6
48,7 - 24Kw (415V)
N 440-480 50/60 3 3+PE 6.5 16 14/2.5
25,3 - 18Kw (440V)
32 8/4
29,8 - 18Kw (480V)
P 380-415 50/60 3 3+PE 9 16 14/2.5
41,7 - 24Kw (380V)
63 6/6
48,7 - 24Kw (415V)
Q 200-240 50/60 3 3+PE N/A
41 - 18Kw (200V)
63 6/6
53,3 - 18Kw (240V)
X 200-240 50/60 1/3 2/3+PE N/A N/A