Loading...
70410501 21
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Troubleshooting
9. Gas Supply Sufficient But Igniter Does Not Glow – Glow-Bar Ignition Gas
Models
Gas supply sufficient but
igniter does not glow -
Glow-Bar Ignition Gas
Models
Has sensor
failed with
contacts open?
Replace sensor.
Is igniter
broken or
open?
Replace glow bar
igniter.
Is there
no circuit
for burner
operation?
Tumbler is not
calling for heat,
check the heat
circuit to the ignition
system.
Yes
Yes
No
Yes
TMB2138S
No

Table of Contents