Gas Requirements
Part No. 70458301ENR7
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 73
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
6,001-8,000
( 1,831-2,440)
22 0.1570 (4.0) M402996 68,400 (72)
8,001-10,000
( 2,441-3,050)
25 0.1495 (3.8) M402997 61,200 (65)
2,001-4,000
( 610-1,220)
14 0.1820 (4.6) M411371 96,600 (102)
4,001-6,000
(1,221-1,830)
16 0.1770 (4.5) M411373 88,200 (93)
6,001-8,000
( 1,831-2,440)
18 0.1695 (4.3) M402988 79,800 (84)
Natural
Gas 60
Hz
8,001-10,000
( 2,441-3,050)
20 0.1610 (4.1) M401002 71,400 (75)
*Btu/hr. derate of 4% per 1,000 feet (305 meters) of altitude.
NOTE: Eco line is only available in natural gas.