EasyManua.ls Logo

Alliance Laundry Systems HTT45N - Page 72

Alliance Laundry Systems HTT45N
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Gas Requirements
72
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No. 70458301ENR7
Altitude Burner Orifice New Rate
Model Gas feet (meters) No.
inches
( mm) Quantity Part No.
Btu/hr.*
(Mj/hr.)
4001-6000
(1,221-1,830)
--- 0.1378 (3.5) 70476601 53,760 (57)
6,001-8,000
( 1,831-2440)
--- 0.1339 (3.4) 44254001 48,640 (51)
8,001-10,000
( 2,441-3,050)
1/8 0.1250 (3.2) M402489 43,520 (46)
2,001-4,000
( 610-1,220)
24 0.1520 (3.9) M402980 68,080 (72)
4,001-6,000
( 1,221-1,830)
26 0.1470 (3.7) M401000 62,160 (66)
6,001-8,000
( 1,831-2,440)
28 0.1405 (3.6) M401014 56,240 (59)
Natural
Gas 50
Hz
8,001-10,000
( 2,441-3,050)
29 0.1360 (---) M400997 50,320 (53)
2,001-4,000
( 610-1,220)
21 0.1590 (4.0) M402992 73,600 (78)
4,001-6,000
( 1,221-1,830)
23 0.1540 (3.9) M401020 67,200 (71)
6,001-8,000
( 1,831-2,440)
26 0.1470 (3.7) M401000 60,800 (64)
T45
Series
Natural
Gas 60
Hz
8,001-10,000
( 2,441-3,050)
28 0.1405 (3.6)
2
M401014 54,400 (57)
2,001-4,000
( 610-1,220)
18 0.1695 (4.3) M402988 82,800 (87)055
Series
Natural
Gas 50
Hz
4,001-6,000
( 1,221-1,830)
20 0.1610 (4.1)
1
M401002 75,600 (80)

Table of Contents

Other manuals for Alliance Laundry Systems HTT45N

Related product manuals