EasyManuals Logo

Allison Transmission 3000 Series User Manual

Allison Transmission 3000 Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
Table5–6.RecommendedFilterChange/FluidChangeIntervals(cont'd)
3000/4000SeriesFluidAndFilterChangeIntervalRecommendations
PrognosticsTurnedOffor
NotCalibratedinTCM
PrognosticsTurnedOn
Duty
Cycle
Allison
Approved
TES668
TM
and/orTES
295
®
Fluid
Allison
Approved
TES389
®
Fluid
Allison
Approved
TES668
TM
and/orTES
295
®
Fluid
Allison
Approved
TES389
®
Fluid
General
*
75,000Miles
(120,000
km)
3,000Hours
36Months
25,000Miles
(40,000km)
1,000Hours
12Months
Lube/
Auxiliary
Filter
Severe
**
75,000Miles
(120,000
km)
3,000Hours
36Months
12,000Miles
(20,000km)
500Hours
6Months
When
indicatedby
controlleror
60months,
whichever
occursrst
When
indicatedby
controlleror
24months,
whichever
occursrst
NOTE:TES389
®
cannotbeusedinMY09.
NOTE:Anythinglessthan100percentconcentrationofTES668
TM
and/orTES
295
®
AllisonapproveduidsisconsideredamixtureandshouldutilizeSchedule
OneTES389
®
changeintervals.Also,mixturesshallnotbeusedwithPrognostics.
*
GeneralVocation:AllvocationsnotclassiedasSevere
**
SevereVocation:On/OffHighway,Refuse,CityTransit,ShuttleTransit
5.9.9.1FLUIDANDFILTERCHANGEPROCEDURE
NOTE:Donotdrainthetransmissionuidifonlyltersarebeing
replaced.
WARNING:Avoidcontactwiththehotuidorthesumpwhen
drainingtransmissionuid.Directcontactwiththehotuidorthehot
sumpmayresultinbodilyinjury.
DrainFluid
1.Draintheuidwhenthetransmissionisatoperatingtemperature
of71–93°C(160–200°F).Hotuidowsquickeranddrainsmore
completely.
107

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allison Transmission 3000 Series and is the answer not in the manual?

Allison Transmission 3000 Series Specifications

General IconGeneral
TypeAutomatic Transmission Controller
Control ModuleIntegrated
Shift Energy ManagementYes
Number of Gears6
Torque ConverterYes, with lock-up clutch
RetarderOptional
PTO ProvisionYes
Input Voltage12V or 24V
Communication ProtocolSAE J1939
Operating Temperature Range-40°C to +85°C

Related product manuals