NOTE:Iftheshiftcalibrationpermitsamaximumallowablegearin
primarymodethatisdifferentthanthemaximumallowablegearin
secondarymode,Prognosticsenabling/disablingisonlypermitted
intheshiftmodewiththehighestmaximumallowablerange.Ifyou
haveahigherrangesetofgearsinsecondarymodethaninprimary
modetoenablePrognostics,pushtheMODEbuttonsoMODE
appearsontheselectordisplayrst.
NOTE:ThethreePrognosticsfunctions,OM,FM,andTM,are
enabledordisabledasapackageandcannotbeenabledordisabled
individually.
5.9.5SETTINGFLUIDTYPEFORPROGNOSTICS.Theuidtypecanbe
programmedwiththeAllisonDOC
®
or,ifthespeciccalibrationallowsit,the
operatorcandothefollowing:
Withtheengineoffandignitionon,performthefollowingsequenceon
theselector,N-R-N-D-N-R-N-D-N-R-N-D-N.
NOTE:Verifyprognosticsuidtypesettingmatchestransmission
uidtypeintransmission.OMnoticationswillbeinaccuratewhen
mismatched.Thiscouldresultintransmissiondamagefromrunning
aTES389
®
uidtoolongorcauseshortenedTES295
®
orTES
668
TM
uidchangestooccur.
AfterrecalibrationofaTCMalwaysverifyprognosticsuidtype
settingiscorrectusingAllisonDOC
®
.Changetheuidtypesetting
usingAllisonDOC
®
ifincorrect.
TheTRANSSERVICEindicatorashesifTES389
®
isthecurrentsettingand
illuminatessolidlyifTES295
®
orTES668
TM
isthecurrentsetting.Tochange
thetransmissionuidtype,wait5secondsafterenteringtransmissionuid
typemodeandperformoneofthefollowingsequencestoselecttheproper
transmissionuidtype:
N(Neutral)R(Reverse)N(Neutral)toselectTES295
®
orTES668
TM
(theTRANSSERVICEindicatorilluminatessolidlyshowingTES295
®
orTES668
TM
hasbeenselected).
N(Neutral)D(Drive)N(Neutral)toselectTES389
®
(theTRANS
SERVICEindicatorbeginstoashshowingTES389
®
hasbeen
selected).
98

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allison Transmission 3000 Series and is the answer not in the manual?

Allison Transmission 3000 Series Specifications

General IconGeneral
TypeAutomatic Transmission Controller
Control ModuleIntegrated
Shift Energy ManagementYes
Number of Gears6
Torque ConverterYes, with lock-up clutch
RetarderOptional
PTO ProvisionYes
Input Voltage12V or 24V
Communication ProtocolSAE J1939
Operating Temperature Range-40°C to +85°C

Related product manuals