Table6–2.DTCListandDescriptions(cont'd)
DTC
Description
CHECK
TRANSLight
InhibitedOperation
Description
P0881
TCMPowerInputSignal
Performance
NoNone
P0882
TCMPowerInputSignal
Low
Yes
DNS,SOLOFF
(hydraulicdefault)
P0883
TCMPowerInputSignal
High
YesNone
P088ATransmissionFilter
MaintenanceAlert
NoNone
P088BTransmissionFilter
MaintenanceRequired
NoNone
P0894UnexpectedMechanical
GearDisengagement
Yes
DNS,Lockinrst
P0897TransmissionFluid
Deteriorated
YesNone
P0960MainPressureModulation
SolenoidControlCircuit
Open
YesFullMainPressure
Commanded
P0961MainPressuerModulation
SolenoidSystem
Performance
NoFullMainPressureis
Commanded
P0962MainPressureModulation
SolenoidControlCircuit
Low
Yes
DNS,SOLOFF
(hydraulicdefault)
P0963MainPressureModulation
SolenoidControlCircuit
High
Yes
DNS,SOLOFF
(hydraulicdefault)
P0964
PressureControl
Solenoid(PCS2)Control
CircuitOpen
Yes
DNS,SOLOFF
(hydraulicdefault)
P0965
PressureControl
Solenoid(PCS2)System
Performance
Yes
TCMforcesVMMoff,
TCMinhibitsTCC
engagement.Hydaulic
default:N(Neutral)3
(ThirdRange)4(Fourth
Range)5(FifthRange)
121

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allison Transmission 3000 Series and is the answer not in the manual?

Allison Transmission 3000 Series Specifications

General IconGeneral
TypeAutomatic Transmission Controller
Control ModuleIntegrated
Shift Energy ManagementYes
Number of Gears6
Torque ConverterYes, with lock-up clutch
RetarderOptional
PTO ProvisionYes
Input Voltage12V or 24V