EasyManuals Logo

Allison Transmission 3000 Series User Manual

Allison Transmission 3000 Series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #128 background imageLoading...
Page #128 background image
Table6–2.DTCListandDescriptions(cont'd)
DTC
Description
CHECK
TRANSLight
InhibitedOperation
Description
P2815
PressureControl
Solenoid(PCS)6Control
CircuitHigh
Yes
DNS,SOLOFF
(hydraulicdefault)
U0073
CANCommunicationBus
1Off
No
Usedefaultvalues
U0074
CANCommunicationBus
2Off
No
Usedefaultvalues
U0100
LostCommunications
withECMA
Yes
Usedefaultvalues
U0103
LostCommunicationWith
GearShiftModule1
Yes
*
Maintainrangeselected,
observegearshift
directioncircuit
**
DependingonOEM
conguration,mayor
maynotallowdirection
changesduringfaults
U0291
LostCommunicationWith
GearShiftModule2
Yes
*
Maintainrangeselected,
observegearshift
directioncircuit
**
DependingonOEM
conguration,mayor
maynotallowdirection
changesduringfaults
U0304
GearShiftModule1
Incompatible
Yes
Ignoreshiftselector
inputs
U0333
GearShiftModule2
Incompatible
Yes
Ignoreshiftselector
inputs
U0400
InvalidCommunication
LinkDataReceived
(J1939BrakeSwitch)
YesNone
U0404
GearShiftModule1
InvalidData
Yes
*
Maintainrangeselected,
observegearshift
directioncircuit
**
DependingonOEM
conguration,mayor
maynotallowdirection
changesduringfaults
127

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allison Transmission 3000 Series and is the answer not in the manual?

Allison Transmission 3000 Series Specifications

General IconGeneral
TypeAutomatic Transmission Controller
Control ModuleIntegrated
Shift Energy ManagementYes
Number of Gears6
Torque ConverterYes, with lock-up clutch
RetarderOptional
PTO ProvisionYes
Input Voltage12V or 24V
Communication ProtocolSAE J1939
Operating Temperature Range-40°C to +85°C