22
$N – SET DEVICE OFFSET FOR ANALOG CHANNELS
Syntax: $N(D)(V)
Where:
(D) is the device (channel) (0-7)
(V) is a desired value.
This command sets the OFFSET parameter for the specified Device.
Note: See Legend for Device (D) location mapping
Response: N(D) = [current value > new value]<CR><LF>
$O – SET DEVICE TARE FOR ANALOG CHANNELS
Syntax: $O(D)(V)
Where:
(D) is the device (channel) (0-7)
(V) is a desired value.
This command sets the TARE parameter for the specified Device. The Tare
Parameter is the value used by the SS LRX to calculate the displayed value. For
a weight channel this value is typically the empty weight of the bucket.
Note: See Legend for Device (D) location mapping
Note: See $T for additional information
Response: O(D) = [current value > new value]<CR><LF>
$P
– PRINT STRING
Syntax: $P(S)
Prints a text string through the PRINTER PORT. The string will have a
<CR><LF> appended to the end when sent out the Auxiliary Port to the printer.
Where:
(S) is the string to be printed
Response: None