EasyManua.ls Logo

Alpha ALPHA6000 Series - P8: Fixed-length Function

Alpha ALPHA6000 Series
243 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Parameter Index
http://www.acdrive-china.com
94
P8: Fixed-length Function
Function
code
Function
Name
LCD Display
Range of settings
Default
Change
MODBUS
Address
P8.00
Preset
length
Preset
length
0.000 (Function
Fixed -length
Stop Invalid)~
65.53m
0.000m
○ 0900
P8.01
Actual
length
Actual
length
0.000~65.53m
(Save when
power loss)
0.000m
* 0901
P8.02
Rate of
length
Rate of
length
0.001~30.00
1.000
○ 0902
P8.03
Correction
Coefficien
t of length
Correction
Coefficient
of length
0.001~1.000
1.000
○ 0903
P8.04
Shaft
perimeter
Shaft
perimeter
0.10~100.0cm
10.00cm
○ 0904
P8.05
Decelerati
on point
Deceleratio
n point
50~100 %
90 % × 0905
P8.06
Deviation
value
Deviation
value
-200.0~200.0
mm
0 mm × 0906

Table of Contents