Alpha E-Tec Plus 28NX, 33NX and 38NX - Commissioning
MODEINFORESET
+
-
+
-
Programming sequence
Fig. 6.10
If you want to exit a parameter without changing its value, press the 'RESET' button.
Press the 'RESET' button or wait for 15 minutes to exit the configuration menu.
MODE
MODE
MODE MODEINFO
INFO
RESET
RESET
RESET
RESET
+
-
+
>5 seconds
G > P> t >A
G > F.1
P.0 > P.22
A.0 > A.11
t.0 > t.15
1 2 3
4
5
1 - Parameter family selection 2 - Parameter selection 3 - Parameter value 4 - Without memorising 5 - Store
Fig. 6.11
The parameter adjustment is saved by pressing the 'MODE' button
after its value has been adjusted, displayed by ' ' flashing for 2
seconds.
ID
Parameter Description
Not used
Not used
DHW min. number
of fan revs
DHW max. number
of fan revs
Ignition phase
number of fan revs
Not used
Not used
G.
n.
S.0
S.1
S.2
F.0
F.1
Default
-
-
E-Tec Plus 28NX NG = 1350 LPG = 1350
E-Tec Plus 33NX NG = 1400 LPG = 1400
E-Tec Plus 38NX NG = 1400 LPG = 1400
E-Tec Plus 28NX NG = 5900 LPG = 5900
E-Tec Plus 33NX NG = 6100 LPG = 6100
E-Tec Plus 38NX NG = 6100 LPG = 6100
E-Tec Plus 28NX 2200
E-Tec Plus 33NX 2500
E-Tec Plus 38NX 2500
-
-
Defines the operating speed of the fan at min.
DHW output
Defines the operating speed of the fan at max.
DHW output
Defines the operating speed of the fan during
the ignition phase
-
-
Customised