trouble shooting
COMBITHERM® CT PROFORMANCE™ SERIES • STEP-BY-STEP PROCEDURES • MN-35948 • 57.
ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E51
No Water In Boiler Lower water level probe B2 is
not satisfi ed within 5 minutes,
after water solenoid valve Y1
is activated
— Water supply is shut off.
— Low water pressure.
— Boiler drain cap missing.
— Boiler drain pump defective.
— Drain pump elbow leaking.
— Water level probe has calcium build up.
— Double water solenoid valve defective (Y1).
— Relay board, high voltage, defective.
E53
Fan Motor High
Temperatures
Fan motor does not spin,
result in over-heating,
detected by motor coil safety
thermo element. Temperature
more than 320°F (160°C).
— Motor high limit open or wired incorrectly.
— If LED on motor control fl ashes, see error codes
for motor control.
— Motor or fan wheel locked.
— Fan wheel damaged.
E54
Lower Fan Motor High
Temperature
Lower fan motor does not
spin, result in over-heating,
detected by motor coil safety
thermo element. Temperature
more than 320°F (160°C).
— Motor high limit open or wired incorrectly.
— If LED on motor control fl ashes, see error codes
for motor control.
— Motor or fan wheel locked.
— Fan wheel damaged.
E55
Vent Not Open 60 seconds after the venting
motor is activated the vent
motor safety switch did not
open.
Alignment issue between motor cam and vent
motor safety switch (micro switch).
Faulty vent valve (motor).
Faulty vent valve safety switch (micro switch).
E56
Vent 2 not open 60 seconds after the venting
motor is activated the vent
motor safety switch did not
open.
Alignment issue between motor cam and vent
motor safety switch (micro switch).
Faulty vent valve (motor).
Faulty vent valve safety switch (micro switch).
E57
No Rinse Water Flow switch for solenoid
valve Y4 does not detect any
water fl ow for a minimum of
60 seconds.
Water supply is shut off.
Low water pressure.
Flow switch is dirty or defective.
Double water solenoid valve defective (Y3).
Relay board, high voltage, defective.
E88
Lower Gas Ignition Failure Reset output from Ignition
Module is ON
— Hot surface ignitor not functioning.
— No gas supply.
— Flame sensor not functioning.
— Faulty ignition control.
E89
Upper Gas Ignition Failure Reset output from Ignition
Module is ON
— Hot surface ignitor not functioning.
— No gas supply.
— Flame sensor not functioning.
— Faulty ignition control.
E90
Lower Gas Combustion
Blower Not at Speed
Speed is too slow. — Power supply cable is not connected to blower
motor.
— Speed control cable is not connected to blower
motor.
— Blower motor is blocked, rotation is impeded, or
motor is faulty.
— Faulty control board.
continued on next page

Questions and Answers: