trouble shooting
COMBITHERM® CT PROFORMANCE™ SERIES • STEP-BY-STEP PROCEDURES • MN-35948 • 58.
ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E91
Upper Gas Blower Not at
Speed
Speed is to slow. — Power supply cable is not connected to blower
motor
— Speed control cable is not connected to blower
motor
— Blower motor is blocked, rotation is impeded, or
motor is faulty
— Faulty control board
E92
Communication Error
CB does not properly
respond
Twelve (12) instances of
no-response from the relay
board (CB) to the display
board (IB).
— Check CAN cable connections mentioned
below.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94
Communication Error,
TO Interface Board
No signal transfer for more
than 5 seconds between the
Interface Board (IB) and the
Control Board (CB).
— Check CAN cable connections mentioned
below.
— CAN cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E100
One or more maintenance
reminder has timed out.
When any maintenance
reminder has expired without
action having been taken by
the operator.
Enter maintenance reminder screen and
address the item that has timed out and reset
E101
Ventless Hood Fault - No
Pressure
If the power switch or
pressure switch is not closed.
Check power switch is on.
Check vent motor is turning in the proper
direction.
— Pressure switch is mis-wired or defective.
— Filter(s) require cleaning or replacement
E102
Ventless Hood Fault —
Filters Not Present
If the air fi lter switches are
not closed.
Check fi lters are installed and properly seated.
Check fi lter switches are not damaged,
defective or dislodged.
E103
Option Board Doesn’t Send
Switch Setting
OB not communicating its
switch settings to the CB.
— Check CAN cable connection between OB and
CB.
— Ensure CB dip switch is set to see an OB.
— Incompatible OB and CB software (update
software).
— OB defective.
— CB defective.
E104
Option Board Not
Communicating
Option board is not
communicating with CB.
— Check option board CAN connection at CB and
OB.
— Defective OB.
— Defective CB.
E105
No or Low Water Pressure Water pressure switch not
activated.
— Water supply not connected.
— Water supply is shut off.
— Water supply to unit blocked or obstructed
— Faulty or miswired pressure switch
E106
Boiler Drain Pump Fault Hall effect or rotational
sensor is not sending a signal
to the relay board
— Drain pump motor not running or defective.
— Hall effect sensor broken or incorrectly wired.
— Motor improperly wired.
continued on next page

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alto-Shaam COMBITHERM CTP6-10e and is the answer not in the manual?

Alto-Shaam COMBITHERM CTP6-10e Specifications

General IconGeneral
BrandAlto-Shaam
ModelCOMBITHERM CTP6-10e
CategoryConvection Oven
LanguageEnglish

Related product manuals