CONTROL UNITS UTR230868 / UTR400868 99
SETTINGS
6. SETTINGS
The setting is performed using the buttons, the setting inscription is displayed on the control
panel display 14 (g.8 / 9).
button to enter the settings menu and exit the menu
button to enter the setting and conrm the selected value
button for stepping into the menu with increasing; also used to control
opening during setting
button for stepping into the menu with decreasing; also used to control closing
during setting
Y
Table3 presents a general description of entering the settings menu, selecting and conrming,
exiting the settings menu.
Table3
1
Press and hold
within ~5 s, before entering the settings menu
≥ 5s
2
After the inscription P1 appears using
or select the
desired menu P0P8
3
When the desired menu appears, press
4
Using
or select the desired setting from the menu
F0F9
5
When the desired menu appears, press
6
The display shows the set value of the operation parameter setting
(tab.13). The value will be with a dot. Using
or select the
desired setting value for the operation parameter
ATTENTION! For menu P1, see ‘6.1. Setting the end position of doors.
For the menu P2, see ‘6.2. Radio control setting
7
When the desired setting appears, press
.
The inscription will become with a dot, which will mean a change in the
setting value
8
Press the button to exit the settings menu (2–3 times) until a dot
appears on the display.
Y
Automatically exit the settings menu is actuated after 10 minutes
in the standby mode
× 2–3