Input:
• Voltage:18-30VAC
Output:
• Maximum:1ampperterminal(3amptotalforallterminals)
• Temperature control ranges: 45°Fto90°F(7°Cto32°C)Accuracy:±1°F(±0.5°C)
• Differential range: 1°Fto3°F(0.5°Cto1.5°C)
• System congurations:
Single-stageheat,single-stagecoolorsingle-stageheat
pump,gas,oil,electric
• Terminations:R,W,Y,O,B,G,C
Parts Diagrams
Controls Single Stage Heating/
Cooling Systems
Single Stage Heat Pump Systems
Compatible with Gas, Oil or
Electric Systems
Millivolt and Hydronic (water or
steam) System Compatible
Mercury-Free, Environmentally
Safe
ResetSwitch
Electric/Gas
Jumper
Mode
Switch
Fan
Switch
Freeze
Switch
HighTemp.
Switch
NonHP–HP
Jumper
RCWYBOG
GAS
ELEC
SET
ROOM
LO BAT
DIFF
Lowbatterysignal
Temperature
differentialsetting
Roomtemperature
Roomtemperature
setpoint
Specifications
Important Safety Information
• Alwaysturnoffthethermostatbeforeinstalling,removing,cleaning,orservicing;turnoffthepoweratthemain
powersourcebyunscrewingfuseorswitchingoffcircuitbreaker
• Donotswitchto“Cool”ifroomtemperatureisbelow50
°
F(10
°
C);thiscoulddamageyourA/Csystemandcause
injury
• Donotinstallonvoltageshigherthan30VAC
• Allwiringmustconformtolocalandnationalbuildingandelectricalcodesandordinances
• Whilecleaning,donotgetsoapdirectlyonthermostatswitchesorLCDreadout;onlyuseadampclothwithamild
soaptowipeoutsideofthermostatcover
Package Contents/Tools Required
Package includes:Amana
®
2246002
non-programmablethermostatonbase,thermostatcover,wiringlabels,
screwsandwallanchors,batteries(ifapplicable),Installation,OperationandApplicationGuide.
Tools required for installation:Drillwith3/16”bit,hammer,screwdriver.
Installation, Operation &
Application Guide
www.amana-ptac.com
2246002
General Description
• TheAmana
®
2246002thermostatisadigital, mercury-free, non-programmable, electronic thermostat
• Compatiblewithsingle-stageheating systems, heating/cooling systems,andheat pump systems;workswith
gas, oil, or electricsystems
• Compatibleasamaster thermostatinzonedsystemapplications
• Freeze Protection Feature:Protectspipesfromfreezing!Iftheroomtemperaturedropsto40
°
F,thethermostat
automaticallyturnsontheheat;thethermostatmustbeintheHeatposition;worksevenifthebatteriesaredead
• Built-in Compressor Protection for Air Conditioners:ToprotecttheA/C’scompressor,thereisa5-minute
delaybetweenthesystemturningoffandtheA/Cstarting
• System Customization:ChooseFahrenheitorCelsiusdisplay;threeavailabletemperature differential
settings
To Remove Existing Thermostat
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.
2. Removecoverofoldthermostat.Thisshouldexposethewires.
3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.
4. Afterlabelingwires,removewiresfromwireterminals.
5. Removeexistingthermostatbasefromwall.
6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.
To Install Thermostat
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing the fuse
or switching the appropriate circuit breaker to the OFF position before removing the existing
thermostat.
IMPORTANT:Thermostat installation must conform to local and national building and electrical codes and
ordinances.
Note:
Mountthethermostataboutvefeetabovetheoor.Donotmountthethermostatonanoutside
wall,indirectsunlight,behindadoor,orinanareaaffectedbyaventorduct.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.MovetheCool/OFF/HeatswitchtoOFF
.
2. MovetheFAN AUTO/ONswitchtoAUTO.
3. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthetopofthethermostat.
4. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthroughthewireopening
inthebaseofthethermostat).
5. Marktheplacementofthemountingholes.
6. Setthermostatbaseandcoverawayfromworkingarea.
7. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
8. Useahammertotapsuppliedanchorsintomountingholes.
9. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughwireopening.
10. Usesuppliedscrewstomountthermostatbasetowall.
CAUTION!
:
Besureexposedportionofwiresdoesnottouchotherwires.
11. Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwire
isconnectedtotheproperterminal.
12. Setthefan jumpertoelectricorgas/oil,andheatpumpjumpertoNON-HPorHP.
13. Replacecoveronthermostatbysnappingitinplace.
14. Turnonpowertothesystematthemainservicepanel.
Replacing Wiring Labels
Replacetheoldlabelswiththeenclosednewlabels:
Old New Type
F,G G Fancontrolrelay
O O Coolactivereversingvalve
B B Heatactivereversingvalve
Y,Y6 Y Coolingcontrol
H,W,4 W
Heatingcontrol
C Transformer,commonside
M,4,RH,RS,R R Transformer,hotside
C YorC
IftheCterminalisthecoolingcontrol,connecttoYterminal;ifitisthe
commonsideofthetransformer,connecttoCterminal
Non-Programmable Electronic Thermostat

Questions and Answers:

Amana 2246002 Specifications

General IconGeneral
BrandAmana
Model2246002
CategoryThermostat
LanguageEnglish

Summary

Installation and Wiring

To Remove Existing Thermostat

Step-by-step instructions for safely removing the old thermostat.

To Install Thermostat

Detailed steps for installing the new Amana thermostat, including safety precautions.

Replacing Wiring Labels

Guide for replacing old wiring labels with new ones for correct connections.

System Operation and Testing

A Quick Test

Procedure to test the thermostat installation after wiring.

Setting Temperature Controls

Adjusting room temperature and temperature differential settings.

Starting the Thermostat

Steps to put the thermostat into operation mode.