EasyManua.ls Logo

Ametek mAcal User Manual

Ametek mAcal
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual
mAcal
mA loop Calibrator
Copyright 2005 AMETEK DENMARK A/S
Question and Answer IconNeed help?

Do you have a question about the Ametek mAcal and is the answer not in the manual?

Ametek mAcal Specifications

Current Generation IconCurrent Generation
current range0-24mA
current resolution0.01mA
current accuracy0.05% F.S.
max load900 Ohm
Current Measurement IconCurrent Measurement
current measurement range0-24mA
current measurement resolution0.001mA
current measurement accuracy0.05% F.S.
input impedance10 Ohm
Voltage Measurement IconVoltage Measurement
voltage rangeOV to +45V
voltage resolution0.1V
voltage accuracy0.5V
Operating Environment IconOperating Environment
operation temperature-10°C to +40°C
storage temperature-20°C to +50°C
Battery IconBattery
battery life with external loop power200 hours
battery life with internal loop power20 hours with 12mA output
battery types4 types LR6, AA, 1.5V – Alkaline
Power IconPower
mains adapter EU103950, 6V DC/230mA
mains adapter UK103957, 6V DC/230mA
mains adapter US/JAPAN103964, 6V DC/240mA
Weight and Dimensions IconWeight and Dimensions
dimensions174 x 66 x 26mm

Summary

Introduction

Packing List

Lists the items included in the product packaging upon receipt.

Safety Instructions

Operation

Display and Keyboard

Details the functions of the device's keys and the meaning of display segments.

Switching the mAcal On/Off

Explains the procedure for powering the mAcal unit on and off.

How the Current is Generated

Describes how to use the mAcal to source or generate electrical current.

How the Current is Measured

Details the process for measuring electrical current using the mAcal.

How the Voltage is Measured

Explains how to use the mAcal to measure electrical voltage.

How New Parameters are Selected (Setup)

Guides the user through the process of configuring new operating parameters.

Error Situations

Test for “Open Loop”

Describes troubleshooting steps for an "Open Loop" error indication.

Test for Incorrect Polarity

Explains how to address an "Incorrect Polarity" error.

Test for “Overrange”

Provides guidance for resolving "Overrange" error conditions.

Indication of Battery Status

Details the display indicators for battery level and what they mean.

How mAcal is Adjusted (service mode)

Technical Specifications (23°C±3°C)