Model | XG 600-1.4 |
---|---|
Output Voltage | 0-600 V |
Output Current | 0-1.4 A |
Output Type | DC |
Number of Outputs | 1 |
Remote Sensing | Yes |
Cooling | Forced air |
Frequency | 47-63 Hz |
Operating Temperature | 0 to 50°C |
Efficiency | 85% |
Storage Temperature | -40 to 70°C |
Protections | OVP, OCP, OTP |
Instructions for safely connecting the AC input power to the XG power supply models.
Recommendations for selecting appropriate wire sizes and types for connecting loads to the power supply.
Procedures for checking power supply functionality, including power-on and mode operations.
Instructions on how to connect loads to the DC output terminals of the power supply.
Information on various conditions that can cause alarms, their precedence, and display messages.
Explanation of the OVP circuit and how to set the voltage trip point to protect the load.
Procedure for performing a soft reset to restore factory default parameters, excluding calibration constants.
Using analog input sources to control the power supply's output voltage, current, or both.
Information on setting up hardware and connections for different remote interfaces available on the XG.
Steps to configure remote control using the RS-232 interface, including cable connections.
Instructions for setting up the USB connection for remote control, including driver installation.
Procedures for performing gain and offset calibration for the output voltage.
Procedures for performing gain and offset calibration for the output current.
Procedure to calibrate the over voltage protection feature, ensuring voltage calibration is done first.
Steps to take in an emergency to shut down the power supply and disconnect mains and load.