30
ON Uniform Symbology Specification (3-1-3 mod 10)
OFF* None (no check digit required)
OPCC Check Digit
Specifies if the OPCC check digit type will be used with Interleaved 2 of 5:
ON Optical Product Code Council (2-1-2 mod 10)
OFF* None (no check digit required)
Send Check Digit
ON Transmit the Interleaved 2 of 5 check digit with the bar code data.
OFF* The check digit is not transmitted.
Enable Fixed Length
ON Read only Fixed Length Interleaved 2 of 5 bar code labels that match the
lengths defined in “Set Fixed Length #1 - #3” options below. The check
digit can be on or off.
OFF* Disable Fixed Length mode. Read all Interleaved 2 of 5 labels without
regard to length.
<--> 1
Sets the first valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. Valid lengths are 02 to 60 characters. By definition, the lengths
of Interleaved 2 of 5 labels are an even number of characters. The default Fixed
Length is 2 characters.
<--> 2
Sets a second valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. The default length is set to 6 characters.
<--> 3
Sets a third valid Fixed Length for Interleaved 2 of 5. Enter a two-digit value to
enter the length. The default length is set to 6 characters.