8.5 Ex ci ter: Oil chan ge / Oil le vel
•
Un screw oil fill ing plug (2) and oil drain plug (1).
•
Drain-off old oil.
•
Screw-in oil drain screw (1).
•
Fill-in new oil through the oil fill hole (2). See lu bri ca tion plan
for quan tity and qual ity.
•
Re place oil fill ing plug (2).
•
Un screw oil fill ing plug (2), check the oil level again and top up
with oil if nec es sary.
LM22020000-2 HbmG gnu thci dreV nna mmA 8102/20
8. Maintenance machine
63
Dan ger of burns.
When working on the engine there is a danger of
burns from hot oil.
• Wear per so nal pro tec ti ve equip ment (glo ves).
Check / change ex citer oil when its warm.
Dan ger of en vi ron men tal dam age from spilled
used oil.
Used oil is water-polluting.
• Do no al low it to en ter the ground wa ter, wa ter
bod ies, or sew age sys tem.
• Col lect the used oil and dis pose of it ac cord ing
to lo cal en vi ron men tal reg u la tions.
When the dip stick is scre wed in, the op ti mal oil le vel is
bet ween the «MIN» and «MAX» mar kings.