8.7.2 Hydraulic hose lines
1 Ammann Ar ti cle No.
2 Man u fac turer/Month and year of man u fac ture
3 Max. op er at ing pres sure
The func tion of hy drau lic hose lines must be tested at reg u lar in -
ter vals (min i mum once a year) by an ex pert (with a knowl edge of
hy drau lics).
Hose lines must im me di ately be re placed in the fol low ing in -
stances:
Dam age to the outer layer to the in ner lin ing (abra sion marks,
cracks, cuts, etc.).
Brit tle ness of the outer layer (crack ing of hose cov er ing).
Un nat u ral de for ma tions of the hose line. This ap plies to both a
pressureless and pres sur ised con di tion (e.g. layer sep a ra tion,
blis ter for ma tion, crushed ar eas, kinks).
Leaks.
Dam age or de for ma tion of hose fit tings (im paired seal ing
func tion).
Hose slips out of the fit ting.
Cor ro sion of fit ting (de grad ing of func tion and strength).
Im proper in stal la tion.
Use be yond the ex piry date of max. 6 years.
LM22020000-2 HbmG gnu thci dreV nna mmA 8102/20
8. Maintenance machine
66

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ammann APR 4920 and is the answer not in the manual?

Ammann APR 4920 Specifications

General IconGeneral
BrandAmmann
ModelAPR 4920
CategoryPower Tool
LanguageEnglish

Related product manuals