Amtech
6-22
6
C614
PID Display Unit
Selection
1 0 69 1 Select the unit for the PID signal.
=0: No Unit
=3: kg/cm
2
=6: CFM
=9: Amp
=12: Hz
=15: rpm
=18: mA
=21: kWh
=24: m/s
=27: kPa
=30: MGD
=33: kb/s
=36: ppm
=39: Km
3
/h
=42: m
3
/min
=45: kg/h
=48: GPS
=51: gal/h
=54: ft
3
/h
=57: lb/h
=60: inH
2
O
=63: lbsi
=66: d
=69: Nm
=1: %
=4: ºC
=7: m
3
/h
=10: kW
=13: s
=16: kh
=19: mV
=22: hp
=25: dm
3
/s
=28: GPM
=31: inHg
=34: kHz
=37: pps
=40: l/h
=43: kg/s
=46: mbar
=49: gal/s
=52: ft
3
/s
=55: lb/s
=58: FPS
=61: in wg
=64: ms
=67: inWC
=2: PSI
=5: ºF
=8: LPM
=11: V
=14: h
=17: lb ft
=20: W
=23: MWh
=26: bar
=29: ft
=32: FPM
=35: ohm
=38: l/s
=41: m
3
/s
=44: kg/m
=47: Pa
=50: gal/m
=53: ft
3
/m
=56: lb/m
=59: ft/s
=62: ft wg
=65: Mrev
=68: m/min
C615
Sleep Mode
Selection
0 0 1 1 When the sleep mode is selected, the inverter
output is switched OFF, if the frequency
reference (or PID output) remains below the
sleep mode enter frequency for the set time
period. Sleep mode can be used with or without
PID control.
=0: Disable
=1: Enable
C616
Sleep Mode Enter
Frequency
Hz 0.10 0.00 600.00
0.01 This is the frequency used to activate the sleep
mode and turn off the inverter.
C617
Sleep Mode Active
Delay
Sec 0 0 999 1 The inverter output will be turned off if the
frequency reference (or PID output) remains
below sleep mode enter frequency.
C618
Sleep Mode Wake
Up Band
% 5.0 0.0 100.0 0.1 This is set with respect to the max frequency
and used as hysteresis when leaving the sleep
mode. The inverter will be turned on when the
frequency reference (or PID output) exceeds the
sleep mode enter frequency + wake up band.
C619
Sleep Mode Leave
Condition
1 1 2 1 Define the condition to leave the sleep mode.
=1: Freq Ref > C616 Sleep Mode Enter Freq
=2: Freq Ref > A102 Min Freq