READ CAREFULLY THE PRODUCT
INSTALLATION & OPERATION INSTRUCTIONS.
FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE
MANUAL MAY RESULT IN SERIOUS OR FATAL INJURY AND/OR
PROPERTY DAMAGE, AND WILL VOID THE PRODUCT WARRANTY.
THIS PRODUCT MUST BE INSTALLED BY A LICENSED
PROFESSIONAL. FOLLOW ALL APPLICABLE LOCAL AND STATE
CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES,
FOLLOW THE CURRENT EDITIONS OF THE NATIONAL PLUMBING
CODE AND NATIONAL ELECTRIC CODE, AS APPLICABLE.
EXPLOSION OR RUPTURE HAZARD. THE EXPANSION TANK MUST
BE OPERATED SO THAT THE PRESSURE DOES NOT EXCEED THE
MAXIMUM WORKING PRESSURE.
EXPLOSION HAZARD. Failure to follow the
instructions in the accompanying product manual
can cause a rupture or explosion; possibly causing serious or fatal injury,
leaking or flooding and/or property damage.
Use only with potable water system. Do not
operate in a setting with freezing temperatures or
where the temperature can exceed 200°F and do not exceed the
maximum working pressure specified for this Product in the Manual.
Mount vertically only.
Chlorine & Aggressive Water: The water quality
can significantly influence the life of this Product.
You should test for corrosive elements, acidity, total solids and other
relevant contaminants, including chlorine and treat your water
appropriately to insure satisfactory performance and prevent
premature failure.
This Product, like most Products under pressure,
may over time corrode. weaken and burst or
explode, causing serious or fatal injury, leaking or flooding and/or
property damage. To minimize risk, a licensed professional must install
and periodically inspect and service the Product. A drip pan connected
to an adequate drain must be installed if leaking or flooding could cause
property damage. Do not locate in an area where leakage of the tank or
connections could cause property damage to the area adjacent to the
appliance or to lower floors of the structure.
EXPLOSION OR RUPTURE HAZARD A relief
valve must be installed to prevent pressure in
excess of local code requirement or maximum working pressure
designated in the Product Manual, whichever is less. Do not expose
Product to freezing temperatures or temperatures in excess of 200° F.
Do not adjust the pre-charge or re-pressure this Product except for any
adjustments required at the time of initial installation, especially if Product
corroded, damaged or with diminished integrity. Adjustments to pre-
charge must be done at ambient temperature only. Failure to properly
size the Product or follow these instructions may result in excessive strain
on the system lead to Product failure, serious or fatal personal injury,
leakage and/or property damage.
This product can expose you to chemicals including
lead, which is known to the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov.
WELL-X-TROL
®
COMMERCIAL PRE-PRESSURIZED WELL TANKS
INSTALLATION & OPERATION INSTRUCTIONS
Models WX-401(C) through WX-407(C)
Models WX-421 through WX-427
Models WX-447(C) through WX-463C
Models WX-35L(CL) through WX-600-L(CL)
NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal
injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a licensed professional immediately. Current
copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS.
OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS
PROPERTY DAMAGE.

Other manuals for Amtrol Well-X-Trol WX Series

Question and Answer IconNeed help?

Do you have a question about the Amtrol Well-X-Trol WX Series and is the answer not in the manual?

Amtrol Well-X-Trol WX Series Specifications

General IconGeneral
Tank MaterialSteel
OrientationVertical
ColorBlue
Model SeriesWX
Pre-Charge Pressure (PSI)38
ApplicationWater Well
Capacity (Gallons)20
Connection Size (Inches)1.25
CertificationsNSF/ANSI 61

Summary

General Safety and Warnings

Read Installation and Operation Instructions

Emphasizes reading and following all instructions to prevent injury or property damage.

Explosion and Rupture Hazards

Warns about explosion/rupture risk from exceeding pressure limits and improper use.

Operational and Environmental Precautions

Details safe operating conditions, water types, and temperature limits for the product.

Corrosion and Pressure Integrity

Highlights the risk of corrosion, weakening, and potential tank failure over time.

Explosion/Rupture Hazard - Relief Valve

Mandates relief valve installation to prevent over-pressurization and potential rupture.

California Proposition 65 Warning

Informs about potential exposure to lead and its health risks as per California law.

Important General Safety Information

Pre-Charge Adjustment Hazards

Details dangers of adjusting pre-charge on tanks with potential integrity issues.

Maximum Working Pressure and Relief Valve

Specifies maximum pressure limits and the requirement for a relief valve.

Operational and Environmental Safety

Covers safe operating practices, environmental factors, and material requirements.

Maintenance Safety Precautions

Advises on safety measures before performing maintenance on the tank.

Pre-Installation Guidelines

Proper Well-X-Trol Location

Guidance on selecting an appropriate installation location for the tank.

System Connection

Instructions for connecting the tank to the system piping.

Installation Procedures

Adjusting Well-X-Trol Precharge

Steps for checking and adjusting the tank's precharge pressure.

High Pressure Application Air Pressure

Specific steps for setting air pressure in high-pressure applications.

Pressure Switch Settings

Guidance on optimal placement and adjustment of the pressure switch.

Safety Protection Requirements

Mandatory safety measures including relief valve and system drainage.

Fine Tuning Procedure

Detailed steps for fine-tuning system pressure and pump operation.

Replacing Galvanized or Epoxy Lined Tanks

Information on replacing older tank types with Well-X-Trol.

Product Applications

Sprinkler System Application

Use in golf course sprinkler systems for surge and hammer protection.

Municipal Well System Application

Control of sequential pump starts and surge reduction in municipal systems.

Pressure Regulation Station Application

Dampening during high peak loading in pressure regulation stations.

High Pressure Booster Application

Use in high-rise buildings and irrigation systems for booster applications.

Submersible Pump Installation

Diagram and description for installing on-line with a submersible pump.

Jet Pump Installation

Diagram and description for installing on-line with a jet pump.

Warranty Information

One Year Limited Warranty

Details the one-year limited warranty for WX Models.