D625 Users Manual
D625 METER – ELECTRICAL CONNECTIONS
Electrical connections to the D625 meter are very simple – you simply supply DC power (+24 V
DC
)
to the Electronics Package and connect the 4-20mA output (or Frequency output if no processor is
selected) of the electronics package to your controls.
MODEL D625 EX-PROOF ENCLOSURE ELECTRICAL CONNECTIONS
Remove the ELECTRICAL ENCLOSURE COVER, and
the ¾ “NPT PLUG from the electronics assembly.
Connect your electronic cabling to the meter
via cable gland to either of the ¾ “ FNPT
ports located on either side of the enclosure.
The customer interface board terminal block
wiring locations are shown above. Each interface
will be discribed in detail in the following steps.
To power the meter, connect ground to
terminal block 3 pin 1 (black) and +24 VDC to
terminal block 3 pin 2 (red).