EasyManua.ls Logo

Andon KD-7908 User Manual

Andon KD-7908
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DN:KD-7908-SMSY01 V2.0 Operation Guide
Template version:1
1/15
MODEL KD-7908
Fully Automatic Wrist Cuff Blood Pressure Monitor
(ELECTRONIC SPHYGMOMANOMETER)
OPERATION GUIDE
INDEX
IMPORTANT INFORMATION ..................................................................................................................................... 2
PARTS AND DISPLAY INDICATORS ........................................................................................................................ 2
INTENDED USE ........................................................................................................................................................... 3
CONTRAINDICATION .................................................................................................................................................. 3
PRODUCT DESCRIPTION ......................................................................................................................................... 3
SPECIFICATIONS ........................................................................................................................................................ 3
NOTICE .......................................................................................................................................................................... 4
SETUP AND OPERATING PROCEDURES ............................................................................................................. 5
1. BATTERY LOADING ........................................................................................................................................ 5
2. CLOCK AND DATE ADJUSTMENT ................................................................................................................ 6
3. CONNECTING THE CUFF TO THE MONITOR ............................................................................................. 6
4. APPLYING THE CUFF ...................................................................................................................................... 6
5. BODY POSTURE DURING MEASUREMENT ................................................................................................ 7
6. TAKING YOUR BLOOD PRESSURE READING ............................................................................................ 7
7. DISPLAYING STORED RESULTS ................................................................................................................... 8
8. DELETING MEASUREMENTS FROM THE MEMORY ................................................................................ 9
9. ASSESSING HIGH BLOOD PRESSURE FOR ADULTS ................................................................................. 9
10. TECHNICAL ALARM DESCRIPTION ..................................................................................................... 9
11. TROUBLESHOOTING (1) ....................................................................................................................... 10
12. TROUBLESHOOTING (2) ....................................................................................................................... 10
MAINTENANCE .......................................................................................................................................................... 11
EXPLANATION OF SYMBOLS ON UNIT ............................................................................................................... 11
WARRANTY INFORMATION .................................................................................................................................... 12
SERVICE CENTER .................................................................................................................................................... 12
ELECTROMAGNETIC COMPATIBILITY INFORMATION .................................................................................... 12

Questions and Answers:

Andon KD-7908 Specifications

General IconGeneral
ModelKD-7908
Measurement MethodOscillometric
Cuff Size22-32 cm
MemoryYes
Irregular Heartbeat DetectionYes
WHO Blood Pressure Classification IndicatorYes
Power SourceBattery
Measurement Range (Pressure)0-280 mmHg
Memory Capacity60 readings
DisplayLCD
Automatic Shut-offYes
Measurement Range (Pulse)40-199 bpm
Power SupplyBatteries

Summary

Important Information and Product Overview

Normal Blood Pressure Fluctuation

Explains how blood pressure fluctuates throughout the day and night.

Parts and Display Indicators

Identifies the main components and display elements of the blood pressure monitor.

Intended Use

Defines the purpose and target users for the blood pressure monitor.

Contraindications

Lists conditions or individuals for whom the monitor is inappropriate.

Product Description

Details the technology and standards the monitor complies with.

Specifications

Provides technical details such as size, weight, measurement range, and accuracy.

Notices and Precautions

Outlines essential safety guidelines and usage warnings for the device.

Setup and Operating Procedures

Battery Loading

Instructions on how to install and replace batteries in the monitor.

Clock and Date Adjustment

Steps to set the correct time and date on the blood pressure monitor.

Connecting the Cuff to the Monitor

Guide on how to attach the blood pressure cuff to the main unit.

Applying the Cuff

Instructions on correctly positioning the cuff on the wrist for measurement.

Body Posture During Measurement

Details the recommended posture for accurate blood pressure readings.

Taking Your Blood Pressure Reading

Step-by-step guide on how to perform a blood pressure measurement.

Displaying Stored Results

How to access and view previously recorded blood pressure measurements.

Measurement Management and Technical Information

Deleting Measurements from the Memory

Procedure for clearing stored measurement data from the device's memory.

Assessing High Blood Pressure for Adults

Guidelines for classifying blood pressure levels based on WHO standards.

Technical Alarm Description

Explanation of error codes and alarms displayed by the monitor.

Troubleshooting and Maintenance

Troubleshooting (1)

Addresses common issues like abnormal results and irregular heartbeat.

Troubleshooting (2)

Covers error codes and solutions for device malfunctions.

Maintenance

Care instructions for the monitor and cuff to ensure longevity and performance.

Explanation of Symbols on Unit

Defines the meaning of various symbols found on the device.

Support and Compliance Information

Warranty Information

Details regarding the product's warranty coverage and limitations.

Service Center

Contact information for customer support and repair services.

Electromagnetic Compatibility Information

Information on EMC emissions and immunity for the device.

Related product manuals