5.2 Appliance Shutdown
There are two shutdown modes of appliance operation: STANDBY and COMPLETE. The standby mode
removes the ability of the appliances main burners to operate. Complete shutdown turns off the gas
supply to the appliance.
STANDBY Turn the thermostat to the OFF position. Turn the Pilot knob clockwise to the PILOT
position. The cooker is now in Standby and can remain this way for only brief periods of
time. NEVER leave the appliance in standby mode for prolonged periods or overnight.
COMPLETE Turn the thermostat to the OFF position. Depress and turn the Pilot knob counter clock-
wise to the OFF position. The appliance is now completely shut down and can be
cleaned and filtered if desired.
5.3 Power Failure
Caution
DO NOT attempt to operate this appliance during a power outage.
Wait five minutes after the power is restored before attempting to restart the appliance. This will allow time for
any gas that may have accumulated in the burner or tubes to dissipate. To restart the appliance, follow the
appliance start up procedure in this manual.
6 Daily Cleaning
Your appliance should be cleaned every day to maintain peak performance, proper sanitation and appearance.
Perform the following procedures daily.
a. Wipe up any shortening/oil that spills onto the exterior of the appliance. This should be done with
a clean soft cloth while the shortening/oil is still warm.
b. Use warm water with a mild detergent to clean surfaces. Be careful not to get water into the
shortening/oil and be sure to completely remove any detergent from the fry tank. Use a non-
abrasive scouring powder or pad to clean stains if necessary.
Notice
Maintenance and repairs should be performed by qualified personnel. If you are
unsure, contact the factory, factory representative to locate the nearest qualified
Service Company.
7 Thermostat Calibration
7.1 Thermostat Calibration Check (Standard)
Notice
Thermostat calibration requires that the temperature of the appliance be raised above
boiling. If you have water in the tank you will need to drain it, dry it and fill it with
shortening/oil. Follow the filling instructions in this manual.
To check the calibration of your appliance, refer to the following procedure.
a. Remove the tube screen from the tank.
b. Place the tip of a digital thermometer probe in the shortening/oil approximately one inch
above the temperature sensor.