15 Conversion Procedure:
Ensure the appliance is not in use, is in a cooled state and that the tank has been emptied. Do not perform this procedure on
a hot appliance or an appliance filled with hot liquid.
To convert appliance:
1. Close the main gas supply at the supply point.
2. Ensure that the control valve is closed by turning it to the “OFF” position.
3. Remove the regulator on front face of gas control and replace it with the one from the conversion kit.
4. Undo and remove the wingnuts from the top of the burners. Remove the wingnuts and burner retainer plate.
5. Remove burner. This will make removing the pilot (on SLG40) or runner tube (on SLG100) easier.
6. Loosen the brass fitting on the gas valve holding the pilot line.
7. Remove the mounting screws on pilot bracket (SLG40) or ignitor bracket (SLG100)
8. For the SLG40 – Completely remove gas line to pilot and replace pilot orifice.
For the SLG100 – Completely remove the gas line to runner tube, disassemble and replace runner tube orifices.
9. For the SLG40 – Re-assemble pilot and re-install the pilot to appliance.
For the SLG100 – Re-assemble runner tube and re-install it into appliance. Remount the ignitor bracket.
10. Replace main burner injectors.
11. Replace the burners.
12. Install the burner plate and wingnuts. Tighten wingnuts.

Related product manuals