2021/01 Rev. 0.4
OptiMeOptiMe
27 / 38
Problem
Possible
cause
Solution
Milk spouts
from dispensing
outlet
Milk pump speed to
low.
The milk is too hot
Check the milk temperature.
Calibrate the milk temperature
False air enters the
system
Check the milk inlet tube [B]
for cracks.
Shorten or replace if necessary
The milk inlet tube
[B] runs empty
when no milk is
dispensed.
The duckbill valve
does not close
anymore.
Check the duckbill valve [D1]
for:
- Correct assembly
- Correct function and
contamination.
- Clean or replace if neces-
sary.
Art.no. duckbill valve:
1007799
Duckbill valve is
missing, defect or
dirty