2021/01 Rev. 0.4
OptiMeOptiMe
7 / 38
Display Possible cause Solution
E8
MIXER ERROR
Mixer motor stalled.
Mixer motor outputs overloaded
The motor current is over 3000mA.
The control has disabled the mixer
output.
Check whether mixer is contaminated or
incorrectly mounted.
Clean and/or check whether the rotor
turns freely.
Check the motor current in the service
menu 2.07 Hardware test / outputs /
Mixer motor.
A motor current (unloaded) between
300-450mA is OK.
E9
MILK PUMP ERROR
Milk pump motor stalled.
Milk pump motor outputs overloaded
The motor current is over 3000mA.
The control has disabled the milk
pump output.
Check is the internal pump gear is
contaminated.
Check the motor current in the service
menu 2.07 Hardware test / outputs /
Milk motor.
A motor current (unloaded) max. 150
mA is OK.
E10
VALVE ERROR
Valve outputs overloaded.
The valve current is over 2500mA.
The control has disabled the output.
Check the valves and wiring for short
circuits.
E11
INGREDIENT MOTOR
ERROR
Ingredient- motor or canister stalled.
Ingredient motor current is over
600mA.
The control has disabled the output.
Empty the canisters and clean
thoroughly.
Check the motor current of the ingredient
motors in the service menu 2.07 Hard-
ware test / outputs / Ingredient motor.
A motor current (unloaded) between 25-
50mA is OK.
E13
MIXER GROUP ERROR
Mixer and Milk motor output group
overload (current too high).
The control has disabled the outputs.
Carry out the checks as specified for E8
and E9.