5. Execute TP_SEM_CONTCC _4 -23.5 to set the Pass/Fail judgment for Spectrum Emission Mask Frequency
Range 24.95 – 34.9 MHz.
[(16QAM, FullRB) Measurements for BW
Channel_CA
29.9 MHz]
6. Execute TESTPRM TX_MAXPWR_16_F to set Test Parameter to TX1 – Max. Power (16QAM/FullRB).
7. Execute ULRMC_RB 100 to set Common Parameter – UL RMC – Number of RB to 100.
8. Execute ULRMC_RB_SCC1 100 to set Common Parameter – SCC-1 – UL RMC – Number of RB to 100.
(For other Configuration ID setting, Set Common Parameter – PCC/SCC–1 – UL RMC-Number of RB and
Starting RB according to TS36.521–1 Table 6.6.2.1A.1.4.1–1.)
9. Execute steps 9 to 11.
[(16QAM, PartialRB) Measurements for BW
Channel_CA
29.9MHz]
1. Execute TESTPRM TX_MAXPWR_16_P to set Test Parameter to TX1 – Max. Power (16QAM/PartialRB).
2. Execute ULRMC_RB 12 to set Common Parameter – UL RMC – Number of RB to 12.
3. Execute ULRMC_RB_SCC1 0 to set Common Parameter – SCC–1 – UL RMC – Number of RB to 0.
(For other Configuration ID setting, set Common Parameter - PCC/SCC–1 UL RMC-Number of RB and Starting
RB according to TS36.521–1 Table 6.6.2.1A.1.4.1–1.)
4. Execute steps 9 to 11.