Anslut 004809 - Technical Data

Anslut 004809
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
43
TECHNICAL DATA
Rated voltage 230 V
~
50 Hz
Input power 1.1 kW
Cooling power 2.3 kW
Refrigerant R410A (300 g)
Energy class A
Temperature range 17–35°C
Cooling capacity Btu/h
Dehumidifying capacity 2.7 l/h
Air ow 310 l/min
Intended for rooms up to 60 m³
Protection rating IPX0
Noise level 65 dB
Dimensions 35 x 70 x 34 cm
Weight 23.5 kg
DESCRIPTION
1. Control panel
2. Receiver for remote control signal
3. Lever for horizontal adjustment of air
deector
4. Lever for vertical adjustment of air deector
5. Wheel
6. Handle
7. Air lter
8. Top air inlet
9. Drain opening
10. Air outlet
11. Bottom air inlet
12. Drain opening for tank
FIG. 1
FIG. 2
Control panel
FIG. 3
MODE
Used to select operating mode. Continue
pressing to switch between COOL, FAN and DRY
modes. The status light indicates the set mode.
NOTE:
The fan speed is controlled automatically
in these modes. The fan speed can only be
adjusted manually in COOL and FAN mode.
– +
The set values are increased (+) and reduced
(–) by pressing –/+. The set point temperature
is increased/reduced in steps of 1°C from 17 to
30°C, or in steps of 1°F from 62 to 88°F.
NOTE:
The temperature can be shown in °F or °C. To
change units, press the + and – buttons at the
same time for 3 seconds.
Power
The power switch starts or switches o the
appliance.
LED display
The display shows the set point
temperature in COOL mode. The room
temperature is shown in DRY and FAN
mode.
The display also shows any error codes or
warning codes:
E1 Error on room temperature sensor.
E2 Error on evaporator temperature
sensor.
E4 Display communication error.
EC Leakage of refrigerant detected.
P1 The tank is full. Drain o the water.