13
4.3.2 Enable UPS
Move the UPS Enable switch to the on ( I ) position.
When shipped, this switch is in the off position to
prevent accidental activation of the UPS. The batteries
will not appreciably discharge if this switch is left on.
Allow the UPS to charge its battery for at least 8 hours before use. The UPS
recharges its battery whenever the utility voltage is normal and UPS Enable
switch is on. While the UPS was shipped from the factory with the batteries
in a fully charged state, the batteries may lose some charge during shipping
and storage. You may use the UPS immediately without charging but the
Low Battery indicator may light, and backup time may be reduced until the
battery has an opportunity to charge.
4.4 Plug loads into UPS
Plug all loads to be protected into the UPS. Do not exceed the UPS’s
capacity as given in Section 9.3. Once switched on, the UPS monitors and
displays the size of the applied load when you press the Test button.
Note: Do not plug laser printers into this UPS. Laser printers
can draw a considerable amount of power, which reduces
the available backup time and, in some cases, causes the
UPS to signal an overload.
4.5 Check site wiring fault indicator—100, 120 Vac versions only
After you connect the loads to the UPS and turn on
the UPS, the Site Wiring Fault indicator on the UPS’s
rear panel should be checked. It will light when the
UPS is plugged into an improperly wired wall outlet. Wiring faults de-
tected include missing ground, hot-neutral polarity reversal, and over-
loaded neutral circuit.
Note: If the UPS indicates a site wiring fault, a qualified electrician should be
summoned to correct the building wiring.
4.0 Installation

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the APC 600 and is the answer not in the manual?

APC 600 Specifications

General IconGeneral
Nominal Output Voltage230V
Nominal Input Voltage230V
Output Power Capacity360 Watts / 600 VA
Frequency50/60 Hz
Input ConnectionsIEC 320 C14
Typical Recharge Time6 hours