Avoid direct sunlight, excessive heat, humidity, and fluid contact for safe operation.
Step-by-step guide for connecting the internal battery to the Back-UPS.
Guidance on installing the PowerChute Personal Edition software for system protection.
Details on Battery Backup, Surge Protected, Master, and Controlled outlets and their uses.
Identifies USB, ground screw, Ethernet, and coaxial ports on the Back-UPS unit.
Configure Master/Controlled outlets for energy conservation based on device standby status.
Manage display illumination for Full-Time or Power-Saving modes.
Configure sensitivity for switching to battery power based on voltage fluctuations.
Details on Mute, Power On/Off, and Display buttons and the main display interface.
Explanation of status indicators like On Line, On Battery, Load Capacity, and AVR.
Descriptions of audible alerts like four beeps, continuous beeping, and chirps.
Visual indicators for overload, battery status, and potential faults.
List of system fault messages (F01-F09) and recommended actions.
Quick reference for button presses, timing, and status for various functions.
Summary of modes like Full-Time/Power-Saving and Master/Controlled outlet settings.
Addresses issues like unit not switching on, no power during outage, and overload indicators.
Guidance on resolving system faults and indicator lights for internal faults.
Detailed technical data including VA, load, voltage, frequency, and dimensions.
Information on battery lifespan, replacement part numbers, and service procedures.
Details on the standard warranty period and how to contact APC customer support.
Avoid direct sunlight, excessive heat, humidity, and fluid contact for safe operation.
Step-by-step guide for connecting the internal battery to the Back-UPS.
Guidance on installing the PowerChute Personal Edition software for system protection.
Details on Battery Backup, Surge Protected, Master, and Controlled outlets and their uses.
Identifies USB, ground screw, Ethernet, and coaxial ports on the Back-UPS unit.
Configure Master/Controlled outlets for energy conservation based on device standby status.
Manage display illumination for Full-Time or Power-Saving modes.
Configure sensitivity for switching to battery power based on voltage fluctuations.
Details on Mute, Power On/Off, and Display buttons and the main display interface.
Explanation of status indicators like On Line, On Battery, Load Capacity, and AVR.
Descriptions of audible alerts like four beeps, continuous beeping, and chirps.
Visual indicators for overload, battery status, and potential faults.
List of system fault messages (F01-F09) and recommended actions.
Quick reference for button presses, timing, and status for various functions.
Summary of modes like Full-Time/Power-Saving and Master/Controlled outlet settings.
Addresses issues like unit not switching on, no power during outage, and overload indicators.
Guidance on resolving system faults and indicator lights for internal faults.
Detailed technical data including VA, load, voltage, frequency, and dimensions.
Information on battery lifespan, replacement part numbers, and service procedures.
Details on the standard warranty period and how to contact APC customer support.
| Output Power Capacity | 600 Watts / 1000 VA |
|---|---|
| Nominal Input Voltage | 120V |
| Input Connections | NEMA 5-15P |
| Cord Length | 1.83 meters |
| Waveform Type | Stepped approximation to a sinewave |
| Interface Port(s) | USB |
| Battery Type | Lead-acid battery |
| Typical Recharge Time | 8 hours |
| Input Frequency | 50/60 Hz (auto-sensing) |
| Audible Alarm | Alarm when on battery, distinctive low battery alarm |
| Dimensions (H x W x D) | 250 x 100 x 382 mm |
| Warranty | 3 years |
| Output Connections | (6) NEMA 5-15R (Battery Backup) |
| Net Weight | 10.72 kg |