Installation and Operation
Back-UPS
®
BE750G Series
Safety
Specifications
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there
is excessive dust or humidity.
Connect the Back-UPS power cord directly to a wall outlet. Do not use a surge
protector or an extension cord.
Input
Voltage 120 Vac Nominal
Frequency 50 Hz/60 Hz auto sensing
Brownout Transfers 92 Vrms Typical
Over-voltage Transfer 139 Vrms Typical
Output
UPS Capacity
(5 battery backup outlets)
750 VA, 450 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vrms ± 8% step approximated sine wave
Frequency - On Battery 50 Hz/60 Hz ± 1 Hz
Transfer Time 6 ms Typical, 10 ms maximum
Protection and
Filtering
AC Surge Protection Full time, 354 Joules
Phone/DSL/FAX surge protection Single line (2 wire)
Cable/CAT V/DSS surge protection One coax input/output
Network surge protection 10/100 Base -T ethernet
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
Replacement battery cartridge RBC17
Average Life 3 - 5 years depending on the number of discharge cycles and
environmental temperature
Physical
Net Weight 11 lb (5 kg)
Dimensions
Length x Width x Height
14 in x 7 in x 4 in
36 cm x 18 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Question and Answer IconNeed help?

Do you have a question about the APC BE750G Series and is the answer not in the manual?

APC BE750G Series Specifications

General IconGeneral
Output Power Capacity450 Watts / 750 VA
Nominal Output Voltage120V
TopologyLine Interactive
Waveform TypeStepped approximation to a sinewave
Input Voltage120V
Input Frequency50/60 Hz +/- 3 Hz (auto sensing)
Battery TypeMaintenance-free sealed Lead-Acid battery with suspended electrolyte
Interface PortUSB
Input Connection TypeNEMA 5-15P
Control PanelLED status indicators
Output Connections8 x NEMA 5-15R
Audible AlarmAlarm when on battery
USB Charging PortsNo
Transfer Time6ms typical
Typical Recharge Time8 Hour(s)

Summary

Safety

Specifications

Input Specifications

Details voltage, frequency, brownout/over-voltage transfers, capacity, and amperage.

Output Specifications

Covers on-battery voltage/frequency, transfer time, and surge protection.

Battery Specifications

Information on AC input, battery type, and average battery life.

Physical Specifications

Details physical attributes like weight, dimensions, operating temperature, humidity, and elevation.

EMC Compliance

FCC compliance statement regarding interference.

Connect the Battery

Wall Mount Installation

Connect Equipment

Battery Backup and Surge Protection Outlets

Explains protection and power for connected devices during outages.

Surge Protection Outlets

Describes protection for devices connected only for surge suppression.

Connect Network and Communication Cables

PowerChute Software

PowerChute Software Overview

Introduces software for advanced power protection and management features.

PowerChute Software Compatibility

Details operating system compatibility and Mac recommendations.

PowerChute Software Installation

Instructions for installing the PowerChute software via CD or download.

Turn On the Back-UPS

Operation

Energy Saving Master and Controlled Outlets

Explains how master/controlled outlets work for energy saving.

Program Threshold Settings

Guide to adjusting threshold settings for master/controlled outlet operation.

Status Indicators

Power On Status

Indicates the Back-UPS is supplying utility power to equipment.

On Battery Status

Shows the Back-UPS supplying battery power to outlets.

Low Battery Warning

Alerts that the battery is near a total discharge state.

Replace Battery Status

Indicates battery is disconnected, needs charging, or replacement.

Overload Shutdown Status

Signals an overload condition during battery operation.

Overload Alarm Status

Alerts to an overload condition while on utility power.

Sleep Mode Status

Indicates the battery is completely discharged.

Building Wiring Fault Status

Warns of a potential electrical hazard in the building wiring.

Voltage Sensitivity Adjustment

Sensitivity Setting Levels

Explains low, medium, and high sensitivity settings for voltage fluctuations.

Troubleshooting

Back-UPS Will Not Turn On

Addresses issues related to the Back-UPS failing to power on.

Power On;Replace Battery LED Flashes

Troubleshoots situations where the Power On/Replace Battery LED is flashing.

Connected Equipment Loses Power

Resolves issues where connected equipment unexpectedly loses power.

Power On LED Illuminated & Beeps

Explains the meaning of the Power On LED illumination and beeping.

Power On LED Flashes & Beeps

Interprets the Power On LED flashing and beeping patterns.

Inadequate Battery Runtime

Addresses problems with insufficient battery backup time.

Building Wiring Fault LED Illuminates

Diagnoses and resolves building wiring fault indicators.

Network;DSL;Modem;FAX Connection Lost

Troubleshoots loss of communication line signal through the Back-UPS.

Replace Battery

Warranty

Service

Service and Support

Details steps for obtaining service, including contacting support and shipping.