APC BACK-UPS RS 800 - User Manual

APC BACK-UPS RS 800
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TVSS GND
Modem/Fax/Phone
Wall
Outlet
Data Por t
Circuit Br eaker
Push t o Reset
Input: 220-240V~, 7A, 50-60Hz
1
0
/
1
0
0
B
a
s
e
-
T
/
V
O
I
P
BATTERY
BACKUP
SURGE ONLY
220-24 0V~, 3A, 50-60Hz , 540W
220-240V~, 3.5A, 50-60Hz, 540W
CONNECT TVSS
Back-UPS
®
RS 800
User’s Manual
2
OPERATING ENVIRONMENT
3
CONNECT EQUIPMENT / POWER
Monitor
Printer or Scanner
FAX
External Disk or
CD / DVD Drive
Computer
4
Phone Jack
CONNECT PHONE/MODEM/FAX
6
CONNECT 10/100 Base-T or VOIP
5
To Computer USB
Port
CONNECT INTERFACE
Computer
8
INSTALL SOFTWARE ON
COMPUTER
There are four status indicators (lights) on the front
panel of the Back-UPS (On Line, On Battery, Overload,
and Replace Battery).
On Line (green) - is lit whenever utility power is
powering the Battery Backup outlets.
On Battery (yellow) - is lit whenever the battery of
the Back-UPS is powering equipment connected to the
Battery Backup Outlets.
Four Beeps Every 30 Seconds - this alarm is
sounded whenever the Back-UPS is running On
Battery. Consider saving work in progress.
Overload (red) - is lit whenever power demand has
exceeded the capacity of the Back-UPS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup outlets are
overloaded.
Circuit Breaker - the circuit breaker button
located on the rear panel of the Back-UPS will
stick out if an overload condition forces the Back-
UPS to disconnect itself from utility power. If the
button sticks out, disconnect non-essential
equipment. Reset the circuit breaker by pushing
the button inward.
Replace Battery (red) - is lit whenever the battery is
near the end of its useful life, or if the battery is not con-
nected (see above). A battery that is near the end of its use-
ful life has insufficient run-time and should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has failed
the automatic diagnostic test.
Note: Allow the Back-UPS to charge for a full eight (8)
hours prior to use.
Press the front panel Power ON/OFF switch and observe
that the following events occur after pressing and
releasing the switch:
The green On Line indicator flashes.
The yellow On Battery indicator lights while
a Self-Test is being performed.
When Self-Test has successfully completed,
only the green On Line indicator will be lit.
If the internal battery cartridge is not
connected (see Step 1 above), the green On
Line indicator and red Replace Battery
indicators will light. The Back-UPS will also
emit a chirping sound.
Continuous Beeping - this alarm is sounded
whenever a low battery condition is reached.
Battery run-time is very low. Promptly save any
work in progress and exit all open applications.
Shutdown the operating system, computer and
the Back-UPS.
NOTE: Macintosh Users - for full USB performance,
use OS 9.22 or higher.
If Autoplay is not enabled on the computer, proceed
as follows:
1. On the computer desktop of the display, double-
click on My Computer.
2. Double-click on the CD-ROM drive icon and
follow the on-screen instructions.
7
SWITCH ON THE BACK-UPS
9
GROUND
The Back-UPS features a transient
voltage surge-suppression (TVSS)
screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.
From Data Line
TVSS
Follow the
on-screen
instructions.
On Line
On Battery
Overload
Replace Battery
RJ-45USB
STATUS INDICATORS AND ALARMS
CABLE
TVSS GND
Modem/Fax/Phone
Wall
Outlet
Data Port
TVSS GND
Modem/Fax/Phone
Wall
Outlet
CONNECT BATTERY CARTRIDGE
1
Computer
Modem Port
Modem/
Wall
Outlet
Data Port
1
0
/
1
0
0
B
a
s
e
-
T
/
V
O
I
P
Network Jack
Computer
Network Port
To 220-240 VAC, 50-60 Hz
Your Computer
Power Cord
0 - 40
o
C (32 - 104
o
F)
30 cm
w
w
w
.apc.com
®
Question and Answer IconNeed help?

Do you have a question about the APC BACK-UPS RS 800 and is the answer not in the manual?

Summary

Initial Setup and Connections

Connect Battery Cartridge

Instructions for connecting the battery cartridge to the Back-UPS unit.

Operating Environment

Specifies the recommended temperature and humidity range for operation.

Connect Equipment and Power

Guide on connecting the Back-UPS to the AC wall outlet and devices.

Connect Communication Lines

Details on connecting phone, modem, or fax lines and network cables.

Connect Interface Cable

Instructions for connecting the Back-UPS to a computer via USB.

Switch On the Back-UPS

Procedure for powering on the unit and observing initial status indicators.

Install Software on Computer

Steps for installing the Back-UPS management software on a PC or Mac.

Connect TVSS Ground

Guidance on connecting ground leads for surge suppression devices.

Status Indicators and Alarms

Front Panel Indicators

Explanation of the On Line, On Battery, Overload, and Replace Battery lights.

Audible Alarms

Description of various sounds indicating battery status or overload conditions.

Troubleshooting and Specifications

Troubleshooting Common Problems

Addresses issues like the unit not switching on or not powering equipment.

Product Specifications

Lists technical details including voltage ranges, load capacity, and dimensions.

Transfer Voltage and Sensitivity Adjustment

Procedure to adjust voltage sensitivity settings for optimal performance.

Service and Support

Service Procedure

Steps to follow if the Back-UPS requires service or repair.

Limited Warranty Information

Details on the standard two-year warranty and replacement policy.

Contact Information

Provides phone numbers and website for technical support.

Summary

Initial Setup and Connections

Connect Battery Cartridge

Instructions for connecting the battery cartridge to the Back-UPS unit.

Operating Environment

Specifies the recommended temperature and humidity range for operation.

Connect Equipment and Power

Guide on connecting the Back-UPS to the AC wall outlet and devices.

Connect Communication Lines

Details on connecting phone, modem, or fax lines and network cables.

Connect Interface Cable

Instructions for connecting the Back-UPS to a computer via USB.

Switch On the Back-UPS

Procedure for powering on the unit and observing initial status indicators.

Install Software on Computer

Steps for installing the Back-UPS management software on a PC or Mac.

Connect TVSS Ground

Guidance on connecting ground leads for surge suppression devices.

Status Indicators and Alarms

Front Panel Indicators

Explanation of the On Line, On Battery, Overload, and Replace Battery lights.

Audible Alarms

Description of various sounds indicating battery status or overload conditions.

Troubleshooting and Specifications

Troubleshooting Common Problems

Addresses issues like the unit not switching on or not powering equipment.

Product Specifications

Lists technical details including voltage ranges, load capacity, and dimensions.

Transfer Voltage and Sensitivity Adjustment

Procedure to adjust voltage sensitivity settings for optimal performance.

Service and Support

Service Procedure

Steps to follow if the Back-UPS requires service or repair.

Limited Warranty Information

Details on the standard two-year warranty and replacement policy.

Contact Information

Provides phone numbers and website for technical support.

APC BACK-UPS RS 800 Specifications

General IconGeneral
Nominal Output Voltage120 V
Nominal Input Voltage120 V
Input Voltage120 V
Input Frequency50/60 Hz
Output ConnectionsNEMA 5-15R
Typical recharge time8 hours
Interface Port(s)USB
Audible AlarmYes
Number of Outlets8
Waveform TypeStepped approximation to a sinewave
Communication PortUSB
Output Power Capacity800 VA
Output Frequency50/60 Hz
Control panelLED indicators
Battery TypeLead-Acid