EasyManua.ls Logo

APC BE750G - User Manual

APC BE750G
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation Guide
Back-UPS
BE750G Series
Specifications
Inventory Safety
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in
contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not
blocked. Allow adequate space for proper
ventilation.
The battery typically lasts for two to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality utility power, and frequent
short duration discharges will shorten battery life.
Connect the Back-UPS power cable directly to a wall outlet. Do not use surge
protectors or extension cords.
Input
Voltage 120 Vac Nominal
Frequency 50 Hz/60 Hz auto sensing
Brownout Transfers 92 Vrms Typical
Over-voltage Transfer 139 Vrms Typical
Output
UPS Capacity
(5 battery backup outlets)
750 VA, 450 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vrms ± 8% step approximated sine wave
Frequency - On Battery 50 Hz/60 Hz ± 1 Hz
Transfer Time 6 ms Typical, 10 ms maximum
Protection and
Filtering
AC Surge Protection Full time, 354 Joules
Phone/DSL/FAX surge protection Single line (2 wire)
Cable/CAT V/DSS surge protection One coax input/output
Network surge protection 10/100 Base -T ethernet
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
Replacement battery cartridge RBC17
Average Life 3 - 5 years depending on the number of discharge cycles and
environmental temperature
Physical
Net Weight 11 lb (5 kg)
Dimensions
Length x Width x Height
14 in x 7 in x 4 in
36 cm x 18 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
bu075c
B
a
c
k
-
U
P
S
Question and Answer IconNeed help?

Do you have a question about the APC BE750G and is the answer not in the manual?

APC BE750G Specifications

General IconGeneral
Output power450 W
Input frequency50/60 Hz
Surge energy rating365 J
Output power capacity0.75 kVA
Weight (imperial)10.34 lbs
Dimensions (WxDxH)180 x 343 x 88 mm
Nominal input voltage120 V
Operating temperature (T-T)0 - 40 °F
Non-operating relative humidity (non-condensing)0 - 95 %
Hot-swap batteryYes
Battery recharge time16 h
Typical backup time at full load2.3 min
Typical backup time at half load11.3 min
Cable length1.8 m
CertificationFCC Part 15 Class B/FCC Part 68/NOM/UL 1778
Product colorBlack
Operating altitude0 - 3000 m
Storage temperature (T-T)-15 - 45 °C
Operating relative humidity (H-H)5 - 95 %
Quantity per pallet72 pc(s)
Weight and Dimensions IconWeight and Dimensions
Weight4700 g
Package weight5700 g

Summary

Safety

Specifications

Connect the Battery

Wall Mount Installation

Connect Equipment

Battery Backup + Surge Protection Outlets

Provides power and surge protection for connected equipment, offering battery backup during outages.

Surge Protection Outlets

Offers surge protection for connected equipment, but no battery backup during power outages.

Connect Modem;Telephone;DSL;FAX;10;100 Base-T Network Cable

PowerChute Personal Edition Software

Software Overview and Features

Details the software's capabilities for power protection, management, and monitoring.

Software Compatibility

Lists supported operating systems and provides guidance for Mac users.

Software Installation Guide

Provides step-by-step instructions for downloading and installing the PowerChute software.

Turn On the Back-UPS

Operation

Energy Saving Master and Controlled Outlets

Explains the master/slave outlet functionality for energy saving and automatic device control.

Program Threshold Settings

Guides users on adjusting threshold settings for optimal performance of controlled outlets.

Status Indicators

Voltage Sensitivity Adjustment

Troubleshooting

Replace Battery

Warranty

Service

Contacting APC Customer Support

Provides instructions for contacting support, obtaining an RMA, and shipping for service.

Related product manuals