Instructions for inspecting, handling, and checking the contents of the UPS package.
Guidance on lightening the unit by removing batteries before installation.
Overview of the UPS front panel, including indicators and their meanings.
Describes the UPS buttons and the meaning of various operational indicators.
Sets the interval for automatic UPS self-testing.
Defines a unique identifier for the UPS for network management.
Resets the date when the UPS battery modules are replaced.
Specifies battery charge percentage after shutdown before powering equipment.
Configures alarm delays or disables all alarms.
Sets the interval between receiving a shutdown command and actual shutdown.
Adjusts the warning interval for low battery conditions.
Sets wait time after utility power return before UPS turns on.
Instructions and precautions for replacing the UPS battery modules.
Guidelines for safely shipping the UPS unit, including battery disconnection.
Details the terms and conditions of the UPS product warranty.
Instructions for inspecting, handling, and checking the contents of the UPS package.
Guidance on lightening the unit by removing batteries before installation.
Overview of the UPS front panel, including indicators and their meanings.
Describes the UPS buttons and the meaning of various operational indicators.
Sets the interval for automatic UPS self-testing.
Defines a unique identifier for the UPS for network management.
Resets the date when the UPS battery modules are replaced.
Specifies battery charge percentage after shutdown before powering equipment.
Configures alarm delays or disables all alarms.
Sets the interval between receiving a shutdown command and actual shutdown.
Adjusts the warning interval for low battery conditions.
Sets wait time after utility power return before UPS turns on.
Instructions and precautions for replacing the UPS battery modules.
Guidelines for safely shipping the UPS unit, including battery disconnection.
Details the terms and conditions of the UPS product warranty.
| Noise level | 55 dB |
|---|---|
| Output power | 3500 W |
| Surge energy rating | 480 J |
| Output power capacity | 5 kVA |
| Emergency Power Off (EPO) | Yes |
| I/O ports | DB-9 RS-232 |
| Dimensions (WxDxH) | 130 x 660 x 432 mm |
| Output voltage note | 230 - 240 |
| Nominal input voltage | 230 V |
| Battery technology | Sealed Lead Acid (VRLA) |
| Battery recharge time | 2.5 h |
| Typical backup time at full load | 5 min |
| Typical backup time at half load | 15.4 min |
| Ethernet LAN (RJ-45) ports | 1 |
| Number of output IEC jumpers | 6 |
| Certification | C-tick, CE, EN 50091-1, EN 50091-2, EN 55022 Class A, N 60950, EN 61000-3-2, GOST, VDE |
| Product color | Black |
| Operating altitude | 0 - 3000 m |
| Non-operating altitude | 0 - 15000 m |
| Storage temperature (T-T) | -15 - 45 °C |
| Operating temperature (T-T) | 0 - 40 °C |
| Operating relative humidity (H-H) | 0 - 95 % |
| Weight | 54550 g |
|---|